About |
---|
CALIBRE™ 201-10 is produced in compliance with the US Food and Drug Administration (FDA) and EU food contact regulations. It provides excellent impact resistance, heat distortion resistance and optical clarity. CALIBRE 201-10 product is formulated with mold release. Govt. and Industry Standards: U.S. FDA 21 CFR 177.1580 Underwriters Laboratory (UL) EU food contact 2011/10/EC Applications: Food and processor housings Liquid containers Food utensils Packaging applications&& |
Product Description | |
---|---|
Supplier | Trinseo |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Features | Good Clarity,High impact resistance,Food contact compliance,HB |
Availabilitys | North America,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.20 | g/cm³ | ISO 1183/A |
Density | 1.2 | g/cm³ | ISO 1183-2 |
Melt Flow Rate | |||
300℃,1.20kg | 10 | g/10min | ISO 1133 |
Melt Volume Rate | |||
300℃,1.2 kg | 8.00 | cm³/10min | ISO 1133 |
Shrinkage rate | |||
MD | 0.50 to 0.70 | % | ISO 294-4 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 2300 | MPa | ISO 527-2/50 |
Tensile modulus | 2300 | MPa | ISO 527-2 2 |
tensile strength | |||
fracture | 71.0 | MPa | ISO 527-2/50 |
yield | 60.0 | MPa | ISO 527-2/50 |
yield | 60.0 | MPa | ISO 527-2 2 |
Tensile strain | |||
fracture | 150 | % | ISO 527-2/50 |
yield | 6.0 | % | ISO 527-2/50 |
yield | 6.0 | % | ISO 527-2 2 |
Nominal strain at break | > 50 | % | ISO 527-2 2 |
Bending modulus | 2400 | MPa | ISO 178 |
bending strength | 97.0 | MPa | ISO 178 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | |||
23℃ | 90.0 | kJ/m² | ISO 179/1eA 2 |
-30℃ | 13.0 | kJ/m² | ISO 179/1eA 2 |
Charpy impact strength | |||
23℃ | No Break | ISO 179/1eU 2 | |
-30℃ | No Break | ISO 179/1eU 2 | |
Impact strength of cantilever beam notch | |||
23℃ | 88 | kJ/m² | ISO 180-4A |
Notched impact strength of cantilever beam | |||
23℃ | No Break | ISO 180 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, annealed | 141 | ℃ | ISO 75-2/A |
1.8 MPa, unannealed | 125 | ℃ | ISO 75-2/A |
1.8 MPa | 131 | ℃ | ISO 75-2 2 |
0.45 MPa, annealed | 144 | ℃ | ISO 75-2/B |
0.45 MPa | 145 | ℃ | ISO 75-2 2 |
Vicat Softening Temp | |||
B50 | 149 | ℃ | ISO 306 |
B50 | 149 | ℃ | ISO 306 2 |
Ball pressure temperature | 125 | ℃ | IEC 60335-1 |
Linear coefficient of thermal expansion | |||
MD | 7.0E-5 | 1/℃ | ISO 11359-2 2 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | > 1.0E+15 | ohms·cm | IEC 60093 2 |
Dielectric strength | 17 | kV/mm | IEC 60243-1 2 |
Relative permittivity | |||
100 Hz | 3.00 | IEC 60250 2 | |
1 MHz | 3.00 | IEC 60250 2 | |
Dissipation factor | |||
100 Hz | 1.0E-3 | IEC 60250 2 | |
1 MHz | 2.0E-3 | IEC 60250 2 | |
Compared to the leakage tracing index | |||
2.00 mm | 250 | V | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | UL 94 | ||
1.60 mm | HB | UL 94 | |
3.20 mm | HB | UL 94 | |
Flame retardant level | |||
1.60 mm | HB | ISO 1210 2 | |
Flame retardant level | |||
3.20 mm | HB | ISO 1210 2 | |
Oxygen index | 26 | % | ISO 4589-2 2 |
optical performance | Nominal value | Unit | Test method |
---|---|---|---|
Transmittance | 87.0 to 91.0 | % | ASTM D1003 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted. |
3. 0.079 in/min |
4. This rating not intended to reflect hazards presented by this or any other material under actual fire conditions. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |