CALIBRE™ 2060-3

About
CALIBRE™ 2060-3 Polycarbonate resin is used in medical applications involving steam or ethylene oxide sterilization – though suitability for use in these applications is dependent upon autoclave cycle times and temperatures. CALIBRE 2060-3 provides exceptional clarity, heat resistance, impact strength and has low contamination levels. The CALIBRE 2000 series of resins have been evaluated with respect to ISO 10993-1 (Biological Evaluation of Medical Devices) and are suitable for use in approved medical applications. Main Characteristics Tested under ISO 10993 FDA 21 CFR 177.1580 Lipid resistance Applications Medical application Injection or extrusion applications&&

Product Description
SupplierTrinseo
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesGood Clarity,High impact resistance,Steam sterilized,High pressure disinfection,High Heat Resistance,Ethylene oxide disinfection
AvailabilitysNorth America,Asia Pacific
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.20g/cm³ASTM D792
Density1.20g/cm³ISO 1183/B
Melt Flow Rate
300℃,1.20kg3.5g/10minASTM D1238
300℃,1.20kg3.5g/10minISO 1133
Shrinkage rate
MD0.50 to 0.70%ISO 294-4
MD0.50 to 0.70%ASTM D955
Water absorption rate
Equilibrium, 23 ℃, 50% RH0.32%ISO 62
Equilibrium, 23 ℃, 50% RH0.32%ASTM D570
23℃,24hr0.15%ISO 62
23℃,24hr0.15%ASTM D570

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
23℃No Break ASTM D256
23℃93kJ/m²ISO 180-A
23℃960J/mASTM D256
Notched impact strength of cantilever beam
23℃No Break ISO 180
Dart impact equipped with measuring instruments
23℃,Total Energy93.8JASTM D3763
Tensile impact strength630kJ/m²ASTM D1822

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, annealed143ASTM D648
1.8 MPa, annealed143ISO 75-2/A
1.8 MPa, unannealed132ASTM D648
1.8 MPa, unannealed132ISO 75-2/A
0.45 MPa, annealed146ASTM D648
0.45 MPa, annealed146ISO 75-2/B
Vicat Softening Temp151ASTM D1525 6
B50151ISO 306
Linear coefficient of thermal expansion
MD:-40~82℃6.8E-51/℃ASTM D696

optical performanceNominal valueUnitTest method
Refractive index1.586 ASTM D542
Refractive index1.586 ISO 489
Transmittance
3180 µm89.0%ASTM D1003
Haze
3180 µm1.0%ASTM D1003

MECHANICALNominal valueUnitTest method
Tensile modulus2480MPaASTM D638
Tensile modulus2480MPaISO 527-2/50
tensile strength
fracture72.0MPaISO 527-2/50
fracture72.4MPaASTM D638
yield60.0MPaISO 527-2/50
yield60.0MPaASTM D638
Tensile strain
fracture150%ASTM D638
fracture150%ISO 527-2/50
Bending modulus2410MPaASTM D790
Bending modulus2410MPaISO 178
bending strength96.5MPaASTM D790
bending strength96.0MPaISO 178
Taber abraser45%ASTM D1044
Rockwell hardness ASTM D785
M-level74 ASTM D785
R-level118 ASTM D785

Notes
1. Biocompatibility testing following ISO Guidelines 10993 has been completed on select classic resins in this series. Please consult Styron for details. ISO guidelines include a sensitization test.
2. Typical properties: these are not to be construed as specifications.
3. 2.0 in/min
4. Method I (3 point load), 0.079 in/min
5. 0.079 in/min
6. Rate A (50°C/h), Loading 2 (50 N)
7. 1/8 inch thickness plaque
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.