| About |
|---|
| CALIBRE™ 2061-3 Polycarbonate resin is used in medical applications involving steam or ethylene oxide sterilization – though suitability for use in these applications is dependent upon autoclave cycle times and temperatures. CALIBRE 2061-3 provides exceptional clarity, heat resistance, impact strength, and processability, and has low contamination levels. CALIBRE 2061 has been evaluated by certain biocompatibility tests based on ISO 10993-1 (Biological Evaluation of Medical Devices) and is suitable for use in approved medical applications. This product contains mold release. Main Characteristics Tested under ISO 10993 Applications Medical Applications&& |
| Product Description | |
|---|---|
| Supplier | Trinseo |
| Generic | Polycarbonate |
| Material Status | Commercial: Active |
| Features | Excellent Processability,Good Clarity,High impact resistance,Steam sterilized,High Heat Resistance,Ethylene oxide disinfection,HB,V-2 |
| Availabilitys | North America,Asia Pacific |
| Process Methods | Injection Molding |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.20 | g/cm³ | ASTM D792 |
| Density | 1.20 | g/cm³ | ISO 1183/B |
| Melt Flow Rate | |||
| 300℃,1.20kg | 3.5 | g/10min | ISO 1133 |
| 300℃,1.20kg | 3.5 | g/10min | ASTM D1238 |
| Shrinkage rate | |||
| MD | 0.50 to 0.70 | % | ASTM D955 |
| MD | 0.50 to 0.70 | % | ISO 294-4 |
| Water absorption rate | |||
| Equilibrium, 23 ℃, 50% RH | 0.32 | % | ASTM D570 |
| Equilibrium, 23 ℃, 50% RH | 0.32 | % | ISO 62 |
| 23℃,24hr | 0.15 | % | ISO 62 |
| 23℃,24hr | 0.15 | % | ASTM D570 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Impact strength of cantilever beam notch | |||
| 23℃ | 960 | J/m | ASTM D256 |
| 23℃ | No Break | ASTM D256 | |
| 23℃ | 93 | kJ/m² | ISO 180-A |
| Notched impact strength of cantilever beam | |||
| 23℃ | No Break | ISO 180 | |
| Dart impact equipped with measuring instruments | |||
| 23℃,Total Energy | 93.8 | J | ASTM D3763 |
| Tensile impact strength | 630 | kJ/m² |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 1.8 MPa, annealed | 143 | ℃ | ASTM D648 |
| 1.8 MPa, annealed | 143 | ℃ | ISO 75-2/A |
| 1.8 MPa, unannealed | 132 | ℃ | ISO 75-2/A |
| 1.8 MPa, unannealed | 132 | ℃ | ASTM D648 |
| 0.45 MPa, annealed | 146 | ℃ | ASTM D648 |
| 0.45 MPa, annealed | 146 | ℃ | ISO 75-2/B |
| Vicat Softening Temp | 151 | ℃ | ASTM D1525 7 |
| B50 | 151 | ℃ | ISO 306 |
| Linear coefficient of thermal expansion | |||
| MD:-40~82℃ | 6.8E-5 | 1/℃ | ASTM D696 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Flame retardant level | UL 94 | ||
| 3.00 mm | HB | UL 94 | |
| 0.75 mm | V-2 | UL 94 | |
| 1.50 mm | V-2 | UL 94 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | 2480 | MPa | ASTM D638 |
| Tensile modulus | 2480 | MPa | ISO 527-2/50 |
| tensile strength | |||
| fracture | 72.0 | MPa | ASTM D638 |
| fracture | 72.4 | MPa | ISO 527-2/50 |
| yield | 60.0 | MPa | ISO 527-2/50 |
| yield | 60.0 | MPa | ASTM D638 |
| Tensile strain | |||
| fracture | 150 | % | ISO 527-2/50 |
| fracture | 150 | % | ASTM D638 |
| Bending modulus | 2410 | MPa | ASTM D790 |
| Bending modulus | 2410 | MPa | ISO 178 |
| bending strength | 96.5 | MPa | ASTM D790 |
| bending strength | 96.0 | MPa | ISO 178 |
| Taber abraser | 45 | % | ASTM D1044 |
| Rockwell hardness | ASTM D785 | ||
| M-level | 74 | ASTM D785 | |
| R-level | 118 | ASTM D785 |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 2. 2.0 in/min |
| 3. Method I (3 point load), 0.079 in/min |
| 4. 0.079 in/min |
| 5. 3-points |
| 6. 11.1 ft/sec |
| 7. Rate A (50°C/h), Loading 2 (50 N) |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |