CALIBRE™ MEGARAD™ 2081-10

About
CALIBRE™ MEGARAD 2081-10 Polycarbonate resin provides end-users of radiation sterilized medical devices a color closer to the water-clear look of the natural resin. When exposed to high energy radiation (gamma or electron beam), CALIBRE MEGARAD 2081-10 resin can reduce the color shift by 50% compared to general purpose polycarbonate resins. CALIBRE 2081-10 resin has undergone biocompatibility testing based on ISO 10993 (Biological Evaluation of Medical Devices) and is suitable for use in approved medical applications. Main Characteristics Stabilized for high energy radiation Tested under ISO 10993 Transparent Contains mold release Applications: Medical applications&&

Product Description
SupplierTrinseo
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesBiocompatible
AvailabilitysEurope
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.20g/cm³ASTM D792 , ISO 1183/A
Melt Flow Rate
300℃,1.20kg10g/10minASTM D1238,ISO 1133
Shrinkage rate 
MD0.50 to 0.70%ASTM D955
MD0.50 to 0.70%ISO 294-4
Water absorption rate ASTM D570 , ISO 62
23℃,24hr0.15%ASTM D570,ISO 62
Equilibrium, 23 ℃, 50% RH0.32%ASTM D570,ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃35kJ/m²ISO 179/1eA
Impact strength of cantilever beam notch 
23℃750J/mASTM D256
23℃78kJ/m²ISO 180-A
Notched impact strength of cantilever beam
23℃无断裂 ASTM D256 , ISO 180
Dart impact equipped with measuring instruments
23 ℃, total energy81.3JASTM D3763
Tensile impact strength378kJ/m²ASTM D1822

THERMALNominal valueUnitTest method
Hot deformation temperature 
0.45 MPa, annealed140ASTM D648
1.8 MPa, unannealed122ASTM D648
1.8 MPa, unannealed121ISO 75-2/A
1.8 MPa, annealed137ASTM D648
Vicat Softening Temp 
A50148ASTM D1525
B50143ISO 306
Linear coefficient of thermal expansion
MD:-40~82℃6.8E-51/℃ASTM D696

Electrical performanceNominal valueUnitTest method
Volume resistivity2.0E+17ohms·cmASTM D257
Dielectric strength17kV/mmASTM D149,IEC 60243-1
Dielectric constant ASTM D150
60 Hz3.00 ASTM D150
1 MHz3.00 ASTM D150
Dissipation factor ASTM D150
50 Hz1.0E-3 ASTM D150
1 MHz2.0E-3 ASTM D150

optical performanceNominal valueUnitTest method
Refractive index1.586 ASTM D542 , ISO 489
Transmittance85.0%ASTM D1003
Haze1.0%ASTM D1003

MECHANICALNominal valueUnitTest method
Rockwell hardness ASTM D785
M-level73 ASTM D785
R-level118 ASTM D785
Tensile modulus 
2210MPaASTM D638
2300MPaISO 527-2/50
tensile strength 
yield62.1MPaASTM D638
yield62.0MPaISO 527-2/50
fracture68.3MPaASTM D638
fracture68.0MPaISO 527-2/50
Tensile strain 
yield6.0%ASTM D638
yield6.0%ISO 527-2/50
fracture150%ASTM D638
fracture150%ISO 527-2/50
Bending modulus 
2410MPaASTM D790
2400MPaISO 178
bending strength 
96.5MPaASTM D790
98.0MPaISO 178
Wear resistance45%ASTM D1044

Notes
1. Biocompatibility testing following ISO Guidelines 10993 has been completed on select classic resins in this series. Please consult Styron for details. ISO guidelines include a sensitization test.
2. Typical properties: these are not to be construed as specifications.
3. 2.0 in/min
4. Method I (3 point load), 0.079 in/min
5. 0.079 in/min
6. 3-points
7. 11.1 ft/sec
8. Rate A (50°C/h), Loading 2 (50 N)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.