About |
---|
CALIBRE™ MEGARAD™ 2081-6LR Polycarbonate resin was developed for medical applications requiring improved resistance to lipids over standard polycarbonate resins. When exposed to a 20% intralipid emulsion solution under strained conditions, CALIBRE MEGARAD 2081-6LR exhibits significant property retention compared to standard polycarbonate. It also provides end-users of radiation sterilized medical devices a color closer to the water-clear look of the natural resin. When exposed to high energy radiation (gamma or electron beam), CALIBRE MEGARAD 2081-6LR can reduce the color shift by 50% compared to general purpose polycarbonate resins. CALIBRE MEGARAD 2081-6LR has been evaluated with respect to ISO 10993 (Biological Evaluation of Medical Devices) and is suitable for use in approved medical applications. Main Characteristics Improved lipid resistance Stabilized for high-energy radiation Transparent Contains mold release Tested under ISO 10993 Applications Medical applications&& |
Product Description | |
---|---|
Supplier | Trinseo |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Availabilitys | North America,Latin America |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.20 | g/cm³ | ASTM D792 |
Melt Flow Rate | |||
300℃,1.20kg | 6.0 | g/10min | ASTM D1238 |
Shrinkage rate | |||
MD | 0.50 to 0.70 | % | ASTM D955 |
Water absorption rate | |||
Equilibrium, 23 ℃, 50% RH | 0.32 | % | ASTM D570 |
23℃,24hr | 0.15 | % | ASTM D570 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
23℃ | No Break | ASTM D256 | |
23℃ | 850 | J/m | ASTM D256 |
Dart impact equipped with measuring instruments | |||
23℃,Total Energy | 89.3 | J | ASTM D3763 |
Tensile impact strength | 567 | kJ/m² | ASTM D1822 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, annealed | 142 | ℃ | ASTM D648 |
1.8 MPa, unannealed | 129 | ℃ | ASTM D648 |
0.45 MPa, annealed | 145 | ℃ | ASTM D648 |
Vicat Softening Temp | 151 | ℃ | ASTM D1525 6 |
Linear coefficient of thermal expansion | |||
MD | 6.8E-5 | 1/℃ | ASTM D696 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | 2.0E+17 | ohms·cm | ASTM D257 |
Dielectric strength | 17 | kV/mm | ASTM D149 |
Dielectric constant | ASTM D150 | ||
60 Hz | 3.00 | ASTM D150 | |
1 MHz | 3.00 | ASTM D150 | |
Dissipation factor | ASTM D150 | ||
50 Hz | 1.0E-3 | ASTM D150 | |
1 MHz | 2.0E-3 | ASTM D150 |
optical performance | Nominal value | Unit | Test method |
---|---|---|---|
Refractive index | 1.586 | ASTM D542 | |
Transmittance | 85.0 | % | ASTM D1003 |
Haze | 1.0 | % | ASTM D1003 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 2340 | MPa | ASTM D638 |
tensile strength | |||
fracture | 68.3 | MPa | ASTM D638 |
yield | 65.5 | MPa | ASTM D638 |
Tensile strain | |||
fracture | 130 | % | ASTM D638 |
yield | 6.0 | % | ASTM D638 |
Bending modulus | 2410 | MPa | ASTM D790 |
bending strength | 96.5 | MPa | ASTM D790 |
Taber abraser | 45 | % | ASTM D1044 |
Rockwell hardness | |||
R-level | 118 | ASTM D785 |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |