CYCOLOY™ HC1204HF resin

About
High heat PC/ABS blend offering good flow and excellent impact. For medical devices and pharmaceutical applications. Healthcare management of change, biocompatible (ISO10993 or USP Class VI).&&

Product Description
SupplierSABIC
GenericPC+ABS
Material StatusCommercial: Active
FeaturesHigh impact resistance,Good liquidity,Biocompatible,High Heat Resistance,HB
AvailabilitysAsia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.15g/cm³ASTM D792 , ISO 1183
Melt Flow Rate
260℃,5.0kg24g/10minASTM D1238
Melt Volume Rate ISO 1133
260℃,2.16 kg8.00cm³/10minISO 1133
260℃,5 kg22.0cm³/10minISO 1133
Shrinkage rate Internal Method
MD0.50 to 0.70%Internal Method
MD:3.2 mm0.50 to 0.70%Internal Method
Water absorption rate ISO 62
Saturation, 23 ℃0.60%ISO 62
Equilibrium, 23 ℃, 50% RH0.20%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃30kJ/m²ISO 179/1eA
23℃50kJ/m²ISO 179/1eA
Impact strength of cantilever beam notch 
-30℃480J/mASTM D256
23℃580J/mASTM D256
-30℃30kJ/m²ISO 180-1A
23℃50kJ/m²ISO 180-1A
Dart impact equipped with measuring instruments
23℃,Total Energy54.0JASTM D3763

THERMALNominal valueUnitTest method
Hot deformation temperature 
0.45 MPa, unannealed, 100 mm span122ISO 75-2/Be
1.8 MPa, unannealed, 3.2 mm112ASTM D648
1.8 MPa, unannealed, 100 mm span102ISO 75-2/Ae
Vicat Softening Temp 
130ASTM D1525 11
B50126ISO 306
B120128ISO 306/B120
Ball pressure test
125℃通过 IEC 60695-10-2
Linear coefficient of thermal expansion 
MD:-40~40℃7.2E-51/℃ASTM E831
MD:23~60℃8.0E-51/℃ISO 11359-2
TD:-40~40℃7.2E-51/℃ASTM E831
TD:23~60℃8.0E-51/℃ISO 11359-2
Thermal conductivity coefficient0.20W/m/KISO 8302
Relative temperature index105UL 746
Electrical performance105UL 746
Impact mechanical performance80.0UL 746

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+15ohmsIEC 60093
Volume resistivity> 1.0E+15ohms·cmIEC 60093
Dielectric strength IEC 60243-1
0.8 mm in oil35kV/mmIEC 60243-1
1.6 mm in oil25kV/mmIEC 60243-1
3.2 mm in oil17kV/mmIEC 60243-1
Relative permittivity IEC 60250
50 Hz2.80 IEC 60250
60 Hz2.80 IEC 60250
1 MHz2.70 IEC 60250
Dissipation factor IEC 60250
50 Hz2.0E-3 IEC 60250
60 Hz2.0E-3 IEC 60250
1 MHz7.0E-3 IEC 60250
Compared to the leakage tracing index250VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.20 mmHB UL 94
3.00 mmHB UL 94
Glowing wire flammability index
1.0 mm650IEC 60695-2-12
Extreme oxygen index23%ISO 4589-2

MECHANICALNominal valueUnitTest method
Rockwell hardness
R-level115 ISO 2039-2
Ball hardness
H358/3096.0MPaISO 2039-1
Tensile modulus 
2270MPaASTM D638
2400MPaISO 527-1-2
tensile strength 
yield57.0MPaASTM D638
yield55.0MPaISO 527-2/5 , ISO 527-2/50
fracture47.0MPaASTM D638
fracture45.0MPaISO 527-2/5 , ISO 527-2/50
Tensile strain 
yield5.0%ASTM D638
yield5.0%ISO 527-2/5
yield4.0%ISO 527-2/50
fracture100%ASTM D638
fracture100%ISO 527-2/5
fracture> 50%ISO 527-2/50
Bending modulus 
50 mm span2300MPaASTM D790
2300MPaISO 178
bending strength 
80.0MPaISO 178
Yield, 50 mm span88.0MPaASTM D790
Taber abraser
1000 cycles, 1000 g, CS-17 wheels63.0mgInternal Method

Process Conditions
injectionNominal valueUnitTest method
Drying temperature100 to 110°C
Drying time2.0 to 4.0hr
Recommended maximum moisture content0.020%
Hopper temperature60 to 80°C
Barrel rear temperature230 to 260°C
Barrel middle temperature250 to 290°C
Barrel front temperature250 to 290°C
Nozzle temperature240 to 280°C
Processing (melt) temperature260 to 290°C
Mold temperature60 to 90°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. Tensile Bar
3. 0.20 in/min
4. Type I, 2.0 in/min
5. 0.051 in/min
6. 0.079 in/min
7. Yield
8. 80*10*3 sp=62mm
9. 80*10*3
10. 120*10*4 mm
11. Rate B (120°C/h), Loading 2 (50 N)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.