Delrin® 588P

About

Product Description
SupplierDuPont
GenericParaformaldehyde
Material StatusCommercial: Active
FeaturesExcellent Processability,HB
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.42g/cm³ISO 1183
Melt flow rate15g/10 minISO 1133
Shrinkage rate ISO 294-4
TD1.8%ISO 294-4
MD1.9%ISO 294-4
Water absorption rate
Equilibrium, 23 ℃, 50% RH0.40%ISO 62

MECHANICALNominal valueUnitTest method
Rockwell hardness120ISO 2039/2
tensile strength
yield73.0MPaISO 527
Tensile strain
Fracture, 23 ℃25%ISO 527
Yield, 23 ° C12%ISO 527
Tensile modulus
23℃3.20MPaISO 527

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
23℃8.0kJ/m²ISO 179/1eA

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed97.0ISO 75-1/2
UL RTI, Electrical
0.800 mm50UL 746B
1.50 mm110UL 746B
3.00 mm110UL 746B
UL RTI, Mechanical Shock
0.800 mm50UL 746B
1.50 mm85UL 746B
3.00 mm90UL 746B
UL RTI, no mechanical impact
0.800 mm50UL 746B
1.50 mm90UL 746B
3.00 mm95UL 746B

Electrical performanceNominal valueUnitTest method
Compared to the leakage tracing index
23℃,3.00 mm600VUL 746A

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level 
0.80 mmHB UL 94
1.50 mmHB UL 94
3.00 mmHBUL 94
Flammability level 
0.8 mmHB IEC 60695-11-10
1.5 mmHB IEC 60695-11-10
3.0 mmHBIEC 60695-11-10

Process Conditions
InjectionNominal valueUnitTest method
Melting temperature
10 ° C/min178°CISO 11357- 1/-3
drying temperature80°C“null”
Drying time – hot air dryer2.0 to 4.0hr“null”
Recommended maximum moisture content0.20%“null”
Mold temperature80 to 100°C“null”
Mold Temperature, Optimal90°C“null”

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.