DJSilicone NE–C-2/NE-C-2U

About
Electrical insulating rubber This product has good processability, good electrical insulativity, electrical erosion resistance, hydrophobicity and flame retardance. Its tracking resistance has reached the class 1A4.5. Molding and injection molding type can both meet the process requirements of customers. It is applicable to manufacturing of various composite insulators, surger arresters, insulators and high- & low-voltage electrical fittings for electrical lines of railways and urban light rails.&&

Product Description
SupplierDONGJUE
Generic硅酮
Material StatusCommercial: Active
FeaturesLow or no water absorption,Flame Characteristics,Insulation,Electric mark
AvailabilitysAsia Pacific
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.45 to 1.51g/cm³ASTM D1505

MECHANICALNominal valueUnitTest method
Shore hardness
Shaw’s A58 to 62 ASTM D2240

elastic bodyNominal valueUnitTest method
Tensile permanent deformation< 2%ASTM D412
tensile strength
yield> 4.00MPaASTM D412
Tensile strain
fracture> 300%ASTM D412
tear strength> 13.0kN/mASTM D624

Electrical performanceNominal valueUnitTest method
Volume resistivity> 5.0E+14ohms·cmASTM D257
Dielectric strength> 20kV/mmASTM D149
Dielectric constant3.00 to 4.00 ASTM D150
Dissipation factor< 0.060 ASTM D150

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant levelFV-0 

Supplementary informationNominal valueUnitTest method
Erosion resistance
Erosion depth< 2.50mm
Electric resistance traceTMA4.5 

Notes
1. Typical properties: these are not to be construed as specifications.
2. Die B
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.