About
(DOMAMID 66V0A) Polyamide 66, flame retardant with halogen, for injection moulding&&

Product Description
SupplierDOMO
GenericPA66
Material StatusCommercial: Active
FeaturesFlame Characteristics,Halogenated
AvailabilitysNorth America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.38g/cm³ISO 1183
Shrinkage rate
TD:23℃,72 hrs1.0 to 1.2%
MD:23℃,72 hrs0.90 to 1.1%

MECHANICALNominal valueUnitTest method
Tensile modulus3500MPaISO 527-1-2
tensile strength
yield75.0MPaISO 527-2/50
Tensile strain
fracture15%ISO 527-2/50
Bending modulus3000MPaISO 178
bending strength100MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃6.0kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength
23℃120kJ/m²ISO 179/1eU
Impact strength of cantilever beam notch
23℃5.0kJ/m²ISO 180-1A
Notched impact strength of cantilever beam
23℃110kJ/m²ISO 180/1U

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed205ISO 75-2/B
1.8 MPa, unannealed90.0ISO 75-2/A
Vicat Softening Temp
B50230ISO 306
Melting temperature262ISO 11357-3

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+13ohmsIEC 60093
Volume resistivity1.0E+15ohms·cmIEC 60093
Compared to the leakage tracing index
Solution A350VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Burning rate< 100mm/minFMVSS 302
Flame retardant level
0.80 mmV-0 
3.00 mmV-0 
Glowing wire flammability index
1.0-3.0 mm960IEC 60695-2-12
Igniting temperature of the hot wire
1-3 mm850IEC 60695-2-13

Process Conditions
injectionNominal valueUnitTest method
Drying temperature75 to 85°C
Drying time2.0 to 4.0hr
Processing (melt) temperature270 to 290°C
Mold temperature70 to 90°C

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.