DOW ENDURANCE™ HFDA-0693 BK LS is specially formulated semiconductive, vulcanizable compound designed for use in conventional extrusion practices as a strippable insulation shield for medium voltage power cable. DOW ENDURANCE™ HFDA-0693 BK LS was designed to have excellent extrusion processing. DOW ENDURANCE™ HFDA-0693 BK LS is an easy stripping insulation shield recommended for use over DOW ENDURANCE™ crosslinked polyethylene compounds. This product provides low strip force over a wide temperature range when used in conjunction with Dow insulation materials. Specifications: DOW ENDURANCE™ HFDA-0693 BK LS is designed for use in power distribution cables. Cables with conductor and insulation shielding of DOW ENDURANCE™ HFDA-0693 BK LS, prepared using sound commercial fabrication practice, would be expected to meet the following specifications: ANSI/ICEA: S-94-649, S-97-682, S-93-639 / NEMA WC74 AEIC: CS 8 IEC 60502&& |
Product Description | |
---|---|
Supplier | DOW |
Generic | 热塑性聚酯 |
Material Status | Commercial: Active |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.18 | g/cm³ | ASTM D1505 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | ASTM D638 | ||
fracture | 14.5 | MPa | ASTM D638 |
Fracture, 136 ℃ | 13.8 | MPa | ASTM D638 |
Tensile strain | ASTM D638 | ||
fracture | 280 | % | ASTM D638 |
Fracture, 136 ℃ | 150 | % | ASTM D638 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Embrittlement temperature | < -40.0 | ℃ | ASTM D746 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | |||
23℃ | 25 | ohms·cm | ASTM D991 |
23℃ | 1.0E+2 to 4.0E+2 | ohms·cm | S-66-524 |
90 ℃ | 30 | ohms·cm | ASTM D991 |
90 ℃ | 1.0E+2 to 4.0E+2 | ohms·cm | S-66-524 |
110 ℃ | 30 | ohms·cm | ASTM D991 |
110 ℃ | 1.0E+2 to 4.0E+2 | ohms·cm | S-66-524 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
Cable Adhesion Force(Dry Cure,23℃) | 2.1 to 4.2 | kN/m | Internal Method |
Process Conditions | |||
---|---|---|---|
Extrusion | Nominal value | Unit | Test method |
Extruder feed section | 43 to 60 | °C | |
Barrel 1 zone temperature | 82 to 88 | °C | |
Barrel 2 zone temperature | 93 to 99 | °C | |
Barrel 3 zone temperature | 99 to 110 | °C | |
Barrel 4 zone temperature | 104 to 110 | °C | |
Barrel 5 zone temperature | 107 to 110 | °C | |
Melt temperature | 115 to 125 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 1 week |
3. on cables |
4. on plaques |
5. Cable adhesion values are typical for dry cure at room temperature. Values will vary with cable size, insulation type, type of cure, temperature, speed of test, etc. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |