Dow ENDURANCE™ HFDC-4202 EC

About
DOW ENDURANCE™ HFDC-4202 EC is a long-life, water-tree-retardant, unfilled, crosslinkable, low density polyethylene insulation compound. The permanent tree-retardant additive provides improved performance in power cables in service involving exposure to moisture while retaining the excellent physical, electrical, and processing attributes of conventional, crosslinkable polyethylene. DOW ENDURANCE™ HFDC-4202 EC compound provides electric utilities with: State-of-the-art “water” tree-retardant technology, consistently outperforming conventional XLPE in all accelerated cable wet aging tests at ambient and elevated temperatures Proven in the field for over 25 years, at a broad cross section of geographical conditions, demonstrating excellent reliability and help achieving lowest life cycle costs Excellent electrical performance demonstrated by very high aged electrical strength and very low aged dissipation factor and power loss. DOW ENDURANCE™ HFDC-4202 EC compound represents the state-of-the-art in tree-retardant, power cable insulation compounds. Specifications DOW ENDURANCE™ HFDC-4202 EC tree-retardant compound is designed for use in power distribution and sub-transmission cables, especially in underground applications. DOW ENDURANCE™ HFDC-4202 EC provides improved performance over XLPE cables and is recommended, with or without moisture barriers, for use as cable insulation up to and including 69 kV applications. Cables insulated with DOW ENDURANCE™ HFDC-4202 EC, using sound commercial fabrication manufacturing practice, would be expected to meet the latest editions of the following specifications and regulations: ANSI/ICEA: S-94-649, S-97-682, S-93-639 / NEMA WC74 (TR-XLPE requirements) AEIC: CS8 RUS 50-70 (U-1) CEA: WCWG-01, WCWG-02 UL 1072 IEC: 60502, 60840 CENELEC: HD 620 S1 DIN VDE 0276-620 BSI BS 6622 GB/T 12706 DL/T 1070&&

Product Description
SupplierDOW
GenericLDPE
Material StatusCommercial: Negative
AvailabilitysNorth America,Latin America,Asia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density0.920g/cm³ASTM D792
The degree of cross combination (Extractables)< 20%ASTM D2765A

MECHANICALNominal valueUnitTest method
tensile strength22.1MPaASTM D638
Tensile strain
fracture530%ASTM D638

Aging performanceNominal valueUnitTest method
Tensile strength retention rate ASTM D638
14 days:150℃> 75%ASTM D638
30 days:121℃> 75%ASTM D638
30 days:136℃> 75%ASTM D638
Elongation retention rate ASTM D638
14 days:150℃> 75%ASTM D638
30 days:121℃> 75%ASTM D638
30 days:136℃> 75%ASTM D638

THERMALNominal valueUnitTest method
High temperature creep
200℃< 100%ICEA T-28-562
thermosetting
200℃< 10%ICEA T-28-562

Electrical performanceNominal valueUnitTest method
Volume resistivity
23℃> 1.0E+15ohms·cmASTM D257
Dielectric strength ASTM D149
3.18 mm26kV/mmASTM D149
3.18 mm23kV/mmASTM D149
Dielectric constant
60 Hz2.30 ASTM D150
Dissipation factor
60 Hz3.0E-4 ASTM D150
Water-Tree Growth Rate10%ASTM D6097
Water-Tree Relative Size25%ASTM D6097

Notes
1. Typical properties: these are not to be construed as specifications.
2. Method A (Short-Time)
3. Method B (Step-by-Step)
4. Rate is relative to rate for Dow’s standard XLPE, FREQ = 1 kHz.
5. Size is relative to size for Dow’s standard XLPE.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.