About |
---|
Product Description | |
---|---|
Supplier | LANXESS |
Generic | PA66 |
Material Status | Commercial: Negative |
Features | Halogen,Glass fiber reinforced,V-0,Flame Characteristics |
Availabilitys | Latin America,North America,Europe,Africa & Middle East ,Asia Pacific |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Shrinkage rate | |||
MD: 150x105x3280 ℃, 50MPa, mold temperature 80 ℃ | 0.23 | % | ISO 2577 |
TD: 150x105x3280 ℃, 50MPa, mold temperature 80 ℃ | 0.81 | % | ISO 2577 |
MD:150x105x3,120℃,4hrs | 0.04 | % | ISO 2577 |
TD:150x105x3,120℃,4hrs | 0.14 | % | ISO 2577 |
Density | 1667 | kg/m³ | ISO 1183 |
Bulk density | 700 | kg/m³ | ISO 60 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Ball hardness | 250 | MPa | ISO 2039 |
Tensile modulus | |||
1.0mm/min | 12400 | MPa | ISO 527 |
tensile strength | |||
Fracture, 5 mm/min | 160 | MPa | ISO 527-1-2 |
elongation at break | |||
5 mm/min | 2.0 | % | ISO 527 |
Bending modulus | |||
2.0mm/min | 10800 | MPa | ISO 178 |
bending strength | |||
2.0mm/min | 235 | MPa | ISO 178 |
Bending strain | |||
2.0mm/min | 2.6 | % | ISO 178 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Unnotch Impact strength | |||
23℃ | 50 | kJ/m² | ISO 179 |
-30℃ | 40 | kJ/m² | ISO 179 |
Impact strength of cantilever beam notch | |||
23℃ | 10 | kJ/m² | ISO 180 |
-30℃ | 10 | KJ/m² | ISO 180 |
Notched impact strength of cantilever beam | |||
23℃ | 45 | kJ/m² | ISO 180 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Compared to the leakage tracing index | |||
1 | PLC Code | IEC 60112 | |
Solution A | 400 | V | IEC 60112 |
Arc resistance | 6 | ASTM D495 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
0.75 mm, full-color | V-0 | UL 94 | |
1.5mm, full-color | V-0 | UL 94 | |
3.0 mm, full-color | V-0 | UL 94 | |
Igniting temperature of the hot wire | |||
0.8 mm | 775 | ℃ | IEC 60695 |
1.5 mm | 775 | ℃ | IEC 60695 |
3.0 mm | 775 | ℃ | IEC 60695 |
Relative temperature of heating wire | |||
0.8 mm | 960 | ℃ | IEC 60695 |
1.5 mm | 960 | ℃ | IEC 60695 |
3.0 mm | 960 | ℃ | IEC 60695 |
Extreme oxygen index | |||
Method A | 39.8 | % | ISO 4589 |
Relative Heat Index (RTI) | |||
Electrical characteristics, 0.75 mm, full-color | 140 | ℃ | UL 746B |
Mechanical impact performance, 0.75 mm, full-color | 90 | ℃ | UL 746B |
Non mechanical impact performance, 0.75 mm, full-color | 115 | ℃ | UL 746B |
Electrical characteristics, 1.5mm, full-color | 140 | ℃ | UL 746B |
Mechanical impact performance, 1.5 mm, full-color | 90 | ℃ | UL 746B |
Non mechanical impact performance, 3.0 mm, full-color | 115 | ℃ | UL 746B |
Electrical characteristics, 3.0 mm, full-color | 140 | ℃ | UL 746B |
Mechanical impact performance, 3.0 mm, full-color | 90 | ℃ | UL 746B |
Non mechanical impact performance, 3.0 mm, full-color | 115 | ℃ | UL 746B |
High voltage arc marking rate (HVTR) | 4 | PLC | UL 746A |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 221 | ℃ | ISO 75 |
0.45 MPa, unannealed | 245 | ℃ | ISO 75 |
Melting temperature | |||
10℃ / min | 260 | ℃ | ISO 11357 |
Linear coefficient of thermal expansion | |||
MD:23~55℃ | 3.0E-5 | m/m/K | ISO 11359 |
TD:23~55℃ | 8.0E-5 | m/m/K | ISO 11359 |
Process Conditions | |||
---|---|---|---|
Injection Molding | Nominal value | Unit | Test method |
drying temperature | 80 | ℃ | |
Drying time | 2 – 6 | hrs | |
Suggested moisture content | ≤0.07 | % | |
Melting temperature | 270 – 290 | ℃ | |
Mold temperature | 80 – 100 | ℃ |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |