EMERGE™ PC/ABS 7700

About
EMERGE™ PC/ABS 7700 Advanced Resin is an ignition-resistant PC/ABS blend that contains no chlorine or bromine additives. It has superior processability for injection molding applications. This grade has excellent aesthetics, is UV stabilized and is available in custom colors. Main Characteristics: Tested under ISO 10993 (Parts 5 & 10) RoHS Compliant Applications: Medical equipment housings Consumer Electronics Information technology equipment&&

Product Description
SupplierTrinseo
GenericPC+ABS
Material StatusCommercial: Active
FeaturesWeather resistance is good,Excellent Processability,Good surface appearance,High impact resistance,Halogen free,Flame Characteristics,V-0,5VA,5VB
AvailabilitysNorth America,Latin America,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.17g/cm³ASTM D792
Density1.18g/cm³ISO 1183/B
Melt Flow Rate 
230℃,3.80kg11g/10minASTM D1238
240℃,5.0kg20g/10minASTM D1238
260℃,2.16kg13g/10minISO 1133
Shrinkage rate
MD0.40 to 0.60%ISO 294-4
MD0.40 to 0.60%ASTM D955

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30 ℃, injection molding15kJ/m²ISO 179/1eA
23 ℃, injection molding40kJ/m²ISO 179/1eA
Impact strength of cantilever beam notch ASTM D256
-18 ℃, 3.2mm, injection molding200J/mASTM D256
-7℃440J/mASTM D256
23 ℃, 3.2mm, injection molding480J/mASTM D256
Impact strength of cantilever beam notch ISO 180/A
-30 ℃, injection molding14kJ/m²ISO 180-A
23 ℃, injection molding50kJ/m²ISO 180-A

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed77.0ISO 75-2/A
1.8 MPa, unannealed79.4ASTM D648
0.45 MPa, unannealed90.6ASTM D648
0.45 MPa, unannealed88.0ISO 75-2/B
Vicat Softening Temp104ASTM D1525 2
Vicat Softening Temp 
104ISO 306/A120
B5094.0ISO 306
Linear coefficient of thermal expansion
TD:-40~40℃6.8E-51/℃ASTM D696
MD:-40~40℃6.8E-51/℃ASTM D696

Electrical performanceNominal valueUnitTest method
Surface resistivity5.2E+15ohmsIEC 60093
Volume resistivity1.0E+18ohms·cmIEC 60093
Dielectric strength IEC 60243-1
1.6 mm in oil26kV/mmIEC 60243-1
3.2 mm in oil18kV/mmIEC 60243-1
Relative permittivity IEC 60250
100 Hz2.86 IEC 60250
1 MHz2.80 IEC 60250
Dissipation factor IEC 60250
100 Hz4.0E-3 IEC 60250
1 MHz7.0E-3 IEC 60250

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.50 mmV-0 UL 94
2.00 mm5VB UL 94
2.50 mm5VA UL 94
Glowing wire flammability index IEC 60695-2-12
1.5 mm925IEC 60695-2-12
2.0 mm925IEC 60695-2-12
2.5 mm925IEC 60695-2-12
3.0 mm950IEC 60695-2-12
Extreme oxygen index28%ASTM D2863

MECHANICALNominal valueUnitTest method
Tensile modulus
4 mm, injection molded2560MPaISO 527-1-2
3.20 mm, injection molded2620MPaASTM D638
tensile strength
Fracture, 4 mm, injection molded45.0MPaISO 527-2/50
Fracture, 3.20 mm, injection molded48.3MPaASTM D638
Yield, 4 mm, injection molding55.0MPaISO 527-2/50
Yield, 3.20 mm, injection molding60.0MPaASTM D638
Tensile strain
Fracture, 4 mm, injection molded43%ISO 527-2/50
Fracture, 3.20 mm, injection molded65%ASTM D638
Yield, 4 mm, injection molding3.8%ISO 527-2/50
Yield, 3.20 mm, injection molding3.8%ASTM D638
Bending modulus
3.20 mm, injection molded2690MPaASTM D790
bending strength
3.20 mm, injection molded96.5MPaASTM D790
Rockwell hardness
R-grade, 3.20 mm120 ASTM D785

Process Conditions
injectionNominal valueUnitTest method
Drying temperature82 to 88°C
Drying time3.0 to 4.0hr
Processing (melt) temperature238 to 274°C
Mold temperature60 to 91°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. Rate B (120°C/h), Loading 1 (10 N)
3. This rating not intended to reflect hazards presented by this or any other material under actual fire conditions.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.