FLEX NORYL™ Resin WCD801A

About
Flexible, migration-improved, halogen free extrusion grade intended for evaluation in applications such as wire insulation and cable jacket. Flame performance capable of meeting UL VW1 requirements. 80C end use temperature rating and good heat deformation performance as defined by UL 1581. 80 Shore A hardness. Processing typically conducted on standard extrusion equipment. UL 1581 tests conducted on 2.0 mm wire with 0.12 mm x 20 stranded copper conductor.&&

Product Description
SupplierSABIC
GenericPPO(PPE)+TPE
Material StatusCommercial: Active
FeaturesExcellent Processability,Good flexibility,Halogen free,Flame Characteristics
AvailabilitysNorth America

Technical Data
PHYSICALNominal valueUnitTest method
Density1.10g/cm³ASTM D792
Melt Flow Rate
250℃,5.0kg11g/10minASTM D1238

THERMALNominal valueUnitTest method
Embrittlement temperature< -40.0ASTM D746
UL temperature rating80UL 1581
Heat Deformation(100℃)16%UL 1581

Electrical performanceNominal valueUnitTest method
Volume resistivity3.8E+15ohms·cmIEC 60093
Dielectric strength
2 mm in oil23kV/mmIEC 60243-1
Relative permittivity
50 Hz2.80 
60 Hz2.80 
1 MHz2.80 
Dissipation factor
50 Hz0.030 
60 Hz0.030 
1 MHz4.0E-3 
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
4.00 mmV-0 UL 94
Glowing wire flammability index
3.0 mm650IEC 60695-2-12
Igniting temperature of the hot wire
3 mm750IEC 60695-2-13
Extreme oxygen index26%ISO 4589-2
VW-1Pass UL 1581
Smoke density
Flaming,Ds max:500.0 µm140 
Non-Flaming,Ds max:500.0 µm95 

MECHANICALNominal valueUnitTest method
Shore hardness
Shore A, 30 seconds80 ASTM D2240
tensile strength
fracture16.0MPaUL 1581
fracture12.0MPaASTM D638
Fracture, 113 ℃17.0MPaUL 1581
fracture13.0MPaISO 527-2/50
Tensile strain
fracture210%UL 1581
fracture120%ASTM D638
Fracture, 113 ℃150%UL 1581
fracture120%ISO 527-2/50
Bending modulus
100 mm span80.0MPaASTM D790
90.0MPaISO 178

Process Conditions
Squeeze descriptionNominal valueUnitTest method

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 mm wire with 0.12 mm x 20 stranded copper
3. Type I, 2.0 in/min
4. After 7 days. Tested on 2.0 mm wire with 0.12 mm x 20 stranded copper
5. Type I, 0.20 in/min
6. 6 days, 2.0 mm wire with 0.12 mm x 20 stranded copper
7. 0.49 in/min
8. 2.0mm wire with 0.12 mm x 20 stranded copper
9. 250g, 2.0 mm wire with 0.12 mm x 20 stranded copper
10. Plaque
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.