Genestar™ GN2450

About
GN2450 features high strength and modulus. It is well suited for FPC sliders and IC sockets, as well as other components that require modulus and dimensional precision.&&

Product Description
SupplierKuraray
GenericPA 9T
Material StatusCommercial: Active
FeaturesGood Rigidity
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.73g/cm³ASTM D792
Shrinkage rate
MD:1.0 mm0.10%ASTM D995
TD:1.00 mm0.50%ASTM D995
Water absorption rate
40℃,95% RH0.70%ASTM D570
Melt Flow Rate
320℃,2.16kg15.00g/10minASTM D1238

MECHANICALNominal valueUnitTest method
tensile strength
23℃200MPaASTM D638
Tensile strain
Fracture, 23 ℃4.1%ASTM D638
bending strength
23℃270MPaASTM D790
Bending modulus
23℃14000MPaASTM D790

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed285ASTM D648
Melting temperature306ASTM D4591
Glass transition temperature125ASTM D648
Vicat Softening Temp

Electrical performanceNominal valueUnitTest method
Volumetric resistance1.0E+14Ω.cmASTM D257
Insulation strength
34KV/mmASTM D149
Dielectric constant
10.0 GHz3.8GHzASTM D150
Dissipation factor
10 GHz0.01GHzASTM D150

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
0.75mmV-0UL 94
1.50mmV-0UL 94
3.00mmV-0UL 94
Igniting temperature of the hot wire
0.75 mm930IEC 60695-2-12
1.5 mm930IEC 60695-2-12
3 mm930IEC 60695-2-12
Relative temperature of heating wire
0.75mm960IEC 60695-2-13
1.50mm960IEC 60695-2-13
3.00mm960IEC 60695-2-13

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
23℃110J/mASTM D256

Notes
1. Typical properties: these are not to be construed as specifications.
2. 96 hrs
3. 750kgf
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.