About |
---|
Hoffman PVC 117-110 is a Rigid Polyvinyl Chloride material. It is available in North America. Important attributes of Hoffman PVC 117-110 are: Flame Rated Rigid Typical application of Hoffman PVC 117-110: Plumbing/Piping/Potable Water&& |
Product Description | |
---|---|
Generic | PVC,刚硬 |
Material Status | Commercial: Active |
Features | Good Rigidity,V-0 |
Availabilitys | North America |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.40 | g/cm³ | ASTM D792 |
Shrinkage rate | |||
MD | 0.30 to 0.50 | % | ASTM D955 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Shore hardness | |||
Shaw’s D | 81 | ASTM D2240 | |
Tensile modulus | 2900 | MPa | ASTM D638 |
tensile strength | 50.3 | MPa | ASTM D638 |
Bending modulus | 3030 | MPa | ASTM D790 |
bending strength | 90.3 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
3.2mm | 35 | J/m | ASTM D256 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, annealed | 74.4 | ℃ | ASTM D648 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | V-0 | UL 94 |
Process Conditions | |||
---|---|---|---|
Extrusion | Nominal value | Unit | Test method |
Melt temperature | 149 to 166 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |