Ingeo biopolymer 7032D is a bottle grade resin designed for injection stretch blow molded applications where heat setting is needed. Ingeo biopolymer 7032D can be run on conventional and heat set ISBM equipment typically used for PET. Ingeo biopolymer 7032D is run at lower processing temperatures than PET. Injection stretch blow molded bottles (ISBM) for singe- and two-stage operations. Ideal for applications where heat setting is required, such as: Fruit juices Sports drinks Oils, jams, non-beverage&&

Product Description
GenericPLA
Material StatusCommercial: Active
FeaturesGood Clarity,Good heat sealing,Renewable resources,Biodegradable,Food contact compliance
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.24g/cm³ASTM D792
Melt Flow Rate
210℃,2.16kg7.0g/10minASTM D1238
Shrinkage rate
MD0.30 to 0.50%ASTM D955

filmNominal valueUnitTest method
Carbon dioxide transfer rate2850cm³/m²/24 hrInternal Method
Oxygen permeability675cm³/m²/24 hrASTM D1434
Water vapor transmittance380g·mm/m²/atm/24 hrASTM F1249

THERMALNominal valueUnitTest method
Glass transition temperature12.8 to 15.6ASTM D3417
Crystallization peak temperature
DSC155 to 170ASTM D3418

Process Conditions
injectionNominal valueUnitTest method
Drying temperature65 to 85°C
Drying time4.0 to 6.0hr
Recommended maximum moisture content0.010%
Barrel rear temperature180°C
Barrel middle temperature210°C
Nozzle temperature210 to 220°C
Processing (melt) temperature200 to 220°C
Mold temperature21 to 38°C
Back pressure0.689 to 1.38MPa

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.