PVC COMPOUND CLASS 70C (PVC/F AND ST1) RECOMMENDED FOR INSULATION AND JACKETING OF ELECTRICAL FLEXIBLE WIRES AND CABLES.&&

Product Description
GenericPVC, not specified
Material StatusCommercial: Negative
AvailabilitysLatin America

Technical Data
PHYSICALNominal valueUnitTest method
Density1.33 to 1.39g/cm³IEC 60811-1-3
colourOK ME 12

elastic bodyNominal valueUnitTest method
tensile strength> 12.6MPaIEC 60811-1-2

Electrical performanceNominal valueUnitTest method
Volume resistivity> 1.0E+13ohms·cmNBR 5403

Supplementary informationNominal valueUnitTest method
Maximum Variation of Elongation< 25%IEC 60811-1-2
Maximum Variation of Tensile Strength< 25%IEC 60811-1-2

MECHANICALNominal valueUnitTest method
Shore hardness
Shore A, 15 seconds78 to 82 NBR 7456
tensile strength> 12.6MPaIEC 60811-1-1
Tensile strain
fracture> 150%IEC 60811-1-2
yield> 150%IEC 60811-1-1

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.