| About |
|---|
| LEAD FREE PVC COMPOUND RECOMMENDED FOR COAXIAL CABLE JACKETING. ALSO RECOMMENDED FOR CLASS 75C ENERGY CABLE JACKETING.&& |
| Product Description | |
|---|---|
| Generic | PVC, not specified |
| Material Status | Commercial: Negative |
| Features | Lead content is low to none |
| Availabilitys | Latin America |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.42 to 1.48 | g/cm³ | ASTM D792 |
| Color a | -1.86 to 1.14 | ME 12 | |
| Color b | 1.67 to 4.67 | ME 12 | |
| Color L | 91.0 to 94.0 | ME 12 | |
| colour | OK | ME 12 | |
| elastic body | Nominal value | Unit | Test method |
|---|---|---|---|
| tensile strength | > 17.3 | MPa | IEC 60811-1-2 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Embrittlement temperature | < -15.0 | ℃ | ASTM D746 |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volume resistivity | > 5.0E+13 | ohms·cm | ASTM D257 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Extreme oxygen index | > 31 | % | ASTM D2863 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Shore hardness | |||
| Shore A, 15 seconds | 89 to 93 | ASTM D2240 | |
| tensile strength | > 17.3 | MPa | IEC 60811-1-1 |
| Tensile strain | |||
| fracture | > 180 | % | IEC 60811-1-2 |
| yield | > 240 | % | ASTM D638 |
| Notes |
|---|
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |