About |
---|
不透明的颜色,高粘度,卓越的阻燃性。紫外线稳定。MFR 7.0g/10 min |
Product Description | |
---|---|
Supplier | SABIC |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Features | Weather resistance is good,High Viscosity,Flame Characteristics |
Availabilitys | North America |
Technical Data | |||
---|---|---|---|
MECHANICAL | Nominal value | Unit | Test method |
tensile strength | |||
Yield, Type I, 50 mm/min | 62 | MPa | ASTM D638 |
tensile strength | |||
Fracture, 50 mm/min | 55 | MPa | ASTM D638 |
Tensile strain | |||
Yield, 50 mm/min | 7 | % | ASTM D638 |
Tensile strain | |||
Fracture, 50 mm/min | 90 | % | ASTM D638 |
bending strength | |||
Yield, 1.30 mm/min, 50 mm span | 91 | MPa | ASTM D790 |
Bending modulus | |||
2240 | MPa | ASTM D790 | |
Roche hardness M | 70 | – | ASTM D 785 |
Roche hardness R | 118 | – | ASTM D 785 |
Taber wear and tear | |||
CS-17, 1 kg | 10 | mg/1000cy | ASTM D1044 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Notched impact strength of cantilever beam | |||
23℃ | 3204 | J/m | ASTM D 4812 |
Impact strength of cantilever beam notch | |||
23℃ | 640 | J/m | ASTM D256 |
Tensile impact | |||
S-shaped | 525 | kJ/m² | ASTM D 1822 |
Drop hammer impact | |||
D 3029,23℃ | 169 | J | ASTM D3029 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Vicat Softening Temp | 151 | ℃ | ASTM D1525 |
Hot deformation temperature | |||
1.8 MPa, unannealed, 6.4 mm | 132 | ℃ | ASTM D648 |
0.45 MPa, unannealed, 6.4 mm | 137 | ℃ | ASTM D648 |
Linear coefficient of thermal expansion | |||
MD:-40~95℃ | 6.84E-05 | 1/℃ | ASTM E831 |
Thermal conductivity coefficient | 0.19 | W/m/℃ | ASTM C 177 |
Relative heat index | 130 | ℃ | UL 746B |
Non mechanical impact performance | 130 | ℃ | UL 746B |
Mechanical impact performance | 120 | ℃ | UL 746B |
PHYSICAL | Nominal value | Unit | Test method |
---|---|---|---|
Density | 1.21 | g/cm³ | ASTM D792 |
Specific product | 0.83 | cm³/g | ASTM D 792 |
Water absorption rate | |||
24hr | 0.15 | % | ASTM D570 |
Water absorption rate | |||
Equilibrium, 23 ℃ | 0.35 | % | ASTM D570 |
Equilibrium, 100 ℃ | 0.58 | % | ASTM D570 |
Shrinkage rate | |||
MD:3.2 mm | 0.5 – 0.7 | % | Internal Method |
Melt Flow Rate | |||
300℃,1.20kg | 7 | g/10min | ASTM D1238 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | >1.E+17 | ohms·cm | ASTM D257 |
Dielectric strength | |||
3.2 mm in air | 16.7 | kV/mm | ASTM D149 |
Relative permittivity | |||
50-60 Hz | 3.01 | ASTM D150 | |
1 MHz | 2.96 | ASTM D150 | |
Dissipation factor | |||
50-60 Hz | 0.0009 | ASTM D150 | |
1 MHz | 0.01 | ASTM D150 | |
Arc resistance | |||
Tungsten wire | 7 | PLC Code | ASTM D495 |
Resistance wire ignition | 1 | PLC Code | UL 746A |
High voltage arc resistance | 3 | PLC Code | UL 746A |
High current arc ignition | |||
surface | 5 | PLC Code | UL 746A |
Compared to the leakage tracing index | |||
CTI | 3 | PLC Code | UL 746A |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant rating 94V-0 | 1.49 | mm | UL 94 |
ultraviolet radiation | |||
Water exposure/immersion | F1 | – | UL 746C |
Process Conditions | |||
---|---|---|---|
injection molding | Nominal value | Unit | Test method |
Drying temperature | 120 | °C | |
Drying time | 3 – 4 | hrs | |
Drying time (gradually increasing) | 48 | hrs | |
Maximum water content | 0.02 | % | |
Melt temperature | 310 – 330 | °C | |
Spray nozzle temperature | 305 – 325 | °C | |
Front temperature | 310 – 330 | °C | |
Mid section temperature | 300 – 320 | °C | |
Post stage temperature | 290 – 310 | °C | |
Mold temperature | 80 – 115 | °C | |
Back pressure | 0.3 – 0.7 | MPa | |
Screw speed | 40 – 70 | rpm | |
Shooting cylinder size | 40 – 60 | % | |
Depth of exhaust groove | 0.025 – 0.076 | mm |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |