LEXAN™ LUX9610 Resin

About
LUX9610 is a UV stabilized flame retardant transparent PC featuring non brominated and non chlorinated FR system with good flow and thin wall FR performance providing good color stability under heat exposure. Developed for lightguide and LED applications. It meets WEEE/RoHS requirements for various applications.&&

Product Description
SupplierSABIC
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesHalogen free,V-0,Flame Characteristics,Weather resistance is good,High Viscosity,Good color stability,Good liquidity
AvailabilitysEurope,North America,Asia Pacific
Process MethodsInjection Molding

Technical Data
MECHANICALNominal valueUnitTest method
Rockwell hardness118RASTM D-785
Tensile Stress
Yield, 50 mm/min62MPaISO 527
Break, 50 mm/min58MPaISO 527
Tensile Strain
Yield, 50 mm/min6%ISO 527
Break, 50 mm/min77%ISO 527
Tensile Modulus
1 mm/min2230MPaISO 527
Flexural Stress
Yield, 2 mm/min94MPaISO 178
Flexural Modulus
2 mm/min2250MPaISO 178

IMPACTNominal valueUnitTest method
Izod Unnotched Impact strength of cantilever beam
23℃NBJ/mASTM D4812
80*10*3 +23°CNBKJ/m²ISO 180/1U
80*10*3 -30°CNBKJ/m²ISO 180/1U
Izod Notched Impact strength
23℃760J/mASTM D256
80*10*3 +23°C70KJ/m²ISO 180/1A
80*10*3 -30°C11KJ/m²ISO 180/1A
Multiaxial Instrumented Impact Total Energy130JISO 6603
Charpy notch Impact strength
23℃,80*10*3 sp=62mm68kJ/m²ISO 179/1eA
-30℃,80*10*3 sp=62mm12kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength
23℃,80*10*3 sp=62mmNBkJ/m²ISO 179/1eU
-30℃,80*10*3 sp=62mmNBkJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Linear coefficient of thermal expansion CTE
-40 ℃~40 ℃, flowing flow6.8×10-5/℃ASTM E831
-40 ℃~40 ℃, horizontal xflow6.7×10-5/℃ASTM E831
Specific Heat1.26J/g/℃ASTM C351
0.2W/m/℃ASTM C177
Ball Pressure Test
123℃-127℃PASSESIEC 60695-10-2
Vicat Softening Temperature
B/50143ISO 306
B/120145ISO 306
Hot deformation temperature HDT
1.8 MPa125ISO 75/Af
Relative Temperature Index
Electrical Elec125UL-746B
Mechanical impact Mech w/impact115UL-746B
Non mechanical impact Mech w/o impact125UL-746B

PHYSICALNominal valueUnitTest method
Water Absorption
100℃0.58%ISO 62
23℃0.35%ISO 62
Density1.2g/cm³ISO 1183
Mold Shrinkage
Flow, 3.2 mm0.68%内部
Moisture AbsorptionISO 62
23℃。50%r.h.0.15
Melt Volume Rate
300℃,1.2 kg7cm³/10minISO 1133

OPTICALNominal valueUnitTest method
Light Transmission
2.54 mm>90%ASTM D1003
Haze
2 mm1%内部
1.586ISO 489

ELECTRICALNominal valueUnitTest method
Dielectric Strength
Air, 3.2 mm15kV/mmASTM D149
Relative permittivity
50/60 Hz3.17ASTM D150
1 MHz2.96ASTM D150
Dissipation Factor
50/60 Hz0.0009ASTM D150
1 MHz0.01ASTM D150
Hot wire ignition3PLC CodeUL 746A
High Ampere Arc Ign, surface1PLC CodeUL 746A
Compared Tracking Index3PLC CodeUL 746A
Volume Resistance>1E15ohm·cmIEC 60093

FLAME CHARACTERISTICSNominal valueUnitTest method
UL flame retardant rating UL Recognized
0.3 mmV-2UL 94
1.5 mmV-0UL 94
Glow Wire Flammability Index
0.8 mm750IEC 60695-2-12
1.5 mm850IEC 60695-2-12
1 mm960IEC 60695-2-12
Glow Wire Ignitability Temperature
1.0 mm850IEC 60695-2-13
1.5 mm850IEC 60695-2-13
UV light, water exposure/immersionF2UL 746C

Process Conditions
Injection moldingNominal valueUnitTest method
Drying Temperature120
Drying Time2-4hr
Maximum Moisture Content0.02%
Melt Temperature280-300
Nozzle temperature270-290
Front Zone 3 Temperature280-300
Middle Zone 2 Temperature270-290
Rear Zone 1 Temperature260-280
Hopper Temperature60-80
Mold Temperature80-100

Notes
1. Typical properties: these are not to be construed as specifications.
2. 0.20 in/min
3. Type I, 2.0 in/min
4. 0.051 in/min
5. 0.079 in/min
6. 0.49 in/min
7. at Break
8. 80*10*3 mm
9. 80*10*4 mm
10. Rate A (50°C/h), Loading 2 (50 N)
11. Surface
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.