LEXAN™ XHT2141 resin

About
XHT2141 is a high flow, high heat polycarbonate copolymer. It is available in a range of opaque and limited transparent colors.&&

Product Description
SupplierSABIC
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesHigh liquidity,High Heat Resistance,Copolymer
AvailabilitysNorth America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.20g/cm³ASTM D792
Density1.20g/cm³ISO 1183
Melt Flow Rate
330℃,2.16kg46g/10minASTM D1238
Melt Volume Rate
330℃,2.16 kg43.0cm³/10minISO 1133
Shrinkage rate
MD:3.2 mm0.60 to 0.90%Internal Method
Water absorption rate
Saturation, 23 ℃0.30%ISO 62
Equilibrium, 23 ℃, 50% RH0.23%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus2600MPaASTM D638
Tensile modulus2600MPaISO 527-1-2
tensile strength
fracture60.0MPaASTM D638
fracture60.0MPaISO 527-2/50
yield70.0MPaISO 527-2/50
yield70.0MPaASTM D638
Tensile strain
fracture90%ASTM D638
fracture90%ISO 527-2/50
yield6.5%ISO 527-2/50
yield6.5%ASTM D638
Bending modulus2450MPaISO 178
50 mm span2550MPaASTM D790
bending strength100MPaISO 178
bending strength
Yield, 50 mm span110MPaASTM D790

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃9.0kJ/m²ISO 179/1eA
23℃12kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃No Break ISO 179/1eU
23℃No Break ISO 179/1eU
Impact strength of cantilever beam notch ASTM D256
-30℃75J/mASTM D256
23℃120J/mASTM D256
Impact strength of cantilever beam notch ISO 180/1A
-30℃9.0kJ/m²ISO 180-1A
-30℃10kJ/m²ISO 180-1A
23℃11kJ/m²ISO 180-1A
23℃10kJ/m²ISO 180-1A
Notched impact strength of cantilever beam ISO 180/1U
-30℃No Break ISO 180/1U
23℃No Break ISO 180/1U
Dart impact equipped with measuring instruments
23℃,Total Energy68.0JASTM D3763

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed, 64 mm span142ISO 75-2/Af
1.8 MPa, unannealed, 3.2 mm145ASTM D648
0.45 MPa, unannealed, 64 mm span155ISO 75-2/Bf
0.45 MPa, unannealed, 3.2 mm155ASTM D648
Vicat Softening Temp161ASTM D1525 11
Vicat Softening Temp 
B50160ISO 306
B120162ISO 306/B120
Ball pressure test
125℃Pass IEC 60695-10-2
Linear coefficient of thermal expansion
TD:-40~40℃6.0E-51/℃ASTM E831
TD:-40~40℃6.0E-51/℃ISO 11359-2
MD:-40~40℃6.0E-51/℃ISO 11359-2
MD:-40~40℃6.0E-51/℃ASTM E831
Thermal conductivity coefficient
25℃0.20W/m/KASTM C177
Relative temperature index
Electrical performance150UL 746
Strength mechanical performance150UL 746
Impact mechanical performance130UL 746

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+17ohmsASTM D257
Volume resistivity> 1.0E+17ohms·cmASTM D257
Dielectric strength
3.2 mm in oil23kV/mmASTM D149
Compared to the leakage tracing indexPLC 3 UL 746
High Arc Burning Index (HAI)PLC 0 UL 746
Hot wire ignition
HWIPLC 3 UL 746

Supplementary informationNominal valueUnitTest method
Metallized Haze Onset155Internal Method

Process Conditions
injectionNominal valueUnitTest method
Drying temperature125°C
Drying time4.0 to 6.0hr
Recommended maximum moisture content0.020%
Recommended injection volume40 to 60%
Barrel rear temperature270 to 305°C
Barrel middle temperature280 to 325°C
Barrel front temperature290 to 335°C
Nozzle temperature285 to 330°C
Processing (melt) temperature290 to 335°C
Mold temperature85 to 130°C
Back pressure0.300 to 0.700MPa
Screw speed40 to 90rpm
Vent depth0.025 to 0.080mm

Notes
1. Typical properties: these are not to be construed as specifications.
2. 0.20 in/min
3. Type I, 2.0 in/min
4. 0.051 in/min
5. 0.079 in/min
6. at Yield
7. 80*10*3 sp=62mm
8. 80*10*4 mm
9. 80*10*3 mm
10. Rate A (50°C/h), Loading 2 (50 N)
11. Surface
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.