About |
---|
LNP* THERMOCOMP* RF0057E is a compound based on Nylon 66 resin containing Glass Fiber, Flame Retardant. Added features of this material include: Non-Brominated & Non-Chlorinated Flame Retardant.&& |
Product Description | |
---|---|
Supplier | SABIC |
Generic | PA66 |
Material Status | Commercial: Active |
Features | Halogen free,Flame Characteristics,V-0,5VA |
Availabilitys | North America |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.39 | g/cm³ | ISO 1183 |
Shrinkage rate | |||
MD:24 hrs | 0.20 to 0.40 | % | ISO 294-4 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 9400 | MPa | ISO 527-1-2 |
tensile strength | |||
fracture | 130 | MPa | ISO 527-2/5 |
Tensile strain | |||
fracture | 2.4 | % | ISO 527-2/5 |
Bending modulus | 8000 | MPa | ISO 178 |
bending strength | 190 | MPa | ISO 178 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
23℃ | 7.0 | kJ/m² | ISO 180-1A |
Notched impact strength of cantilever beam | |||
23℃ | 45 | kJ/m² | ISO 180/1U |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed, 64 mm span | 240 | ℃ | ISO 75-2/Af |
Ball pressure test | |||
240℃ | Pass | IEC 60695-10-2 | |
Relative temperature index | |||
Electrical performance | 140 | ℃ | UL 746 |
Strength mechanical performance | 140 | ℃ | UL 746 |
Impact mechanical performance | 110 | ℃ | UL 746 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | 1.0E+12 | ohms·cm | ASTM D257 |
Dielectric strength | |||
1.6 mm in air | 16 | kV/mm | ASTM D149 |
Compared to the leakage tracing index | 600 | V | IEC 60112 |
High Arc Burning Index (HAI) | PLC 0 | UL 746 | |
Hot wire ignition | |||
HWI | PLC 0 | UL 746 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | UL 94 | ||
0.40 mm | V-0 | UL 94 | |
1.60 mm | 5VA | UL 94 | |
Glowing wire flammability index | |||
0.40 mm | 960 | ℃ | IEC 60695-2-12 |
Igniting temperature of the hot wire | IEC 60695-2-13 | ||
0.4 mm | 775 | ℃ | IEC 60695-2-13 |
1 mm | 775 | ℃ | IEC 60695-2-13 |
1.5 mm | 775 | ℃ | IEC 60695-2-13 |
3 mm | 825 | ℃ | IEC 60695-2-13 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 82 | °C | |
Drying time | 4.0 | hr | |
Recommended maximum moisture content | 0.15 to 0.25 | % | |
Barrel rear temperature | 249 to 260 | °C | |
Barrel middle temperature | 254 to 266 | °C | |
Barrel front temperature | 260 to 271 | °C | |
Processing (melt) temperature | 266 to 277 | °C | |
Mold temperature | 60 to 99 | °C | |
Back pressure | 0.172 to 0.344 | MPa | |
Screw speed | 30 to 60 | rpm |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 0.079 in/min |
3. at Yield |
4. 80*10*4 mm |
5. Approximate Maximum |
6. Surface |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |