Lumiloy® GN1306F

About
Injection Molding Grade, Flame Retardent mPPO Description General Purpose, High Heat Resistance Application Electric and Electronic Parts&&

Product Description
SupplierLG Chemical
GenericPPO(PPE)+PS
Material StatusCommercial: Active
FeaturesFlame Characteristics,High Heat Resistance,V-0
AvailabilitysNorth America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.09g/cm³ASTM D792
Melt Flow Rate
280℃,5.0kg8.0g/10minASTM D1238
Water absorption rate
23℃,24hr0.30%ASTM D570

MECHANICALNominal valueUnitTest method
tensile strength
Yield, 3.20 mm68.6MPaASTM D638
Tensile strain
Fracture, 3.20 mm20%ASTM D638
Bending modulus
3.20 mm2450MPaASTM D790
bending strength
Fracture, 3.20 mm118MPaASTM D790

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch ASTM D256
-40℃,3.2mm78J/mASTM D256
-30℃,3.2mm98J/mASTM D256
23℃,3.2mm200J/mASTM D256

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed, 6.4 mm135ASTM D648

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
0.80 mmV-0 UL 94
1.50 mmV-0 UL 94
2.00 mmV-0 5VA UL 94
3.00 mmV-0 5VA UL 94

Process Conditions
injectionNominal valueUnitTest method
Drying temperature90 to 100°C
Drying time3.0 to 4.0hr
Recommended maximum moisture content> 0.010%
Barrel rear temperature250 to 280°C
Barrel middle temperature260 to 290°C
Barrel front temperature260 to 300°C
Nozzle temperature260 to 300°C
Processing (melt) temperature270 to 300°C
Mold temperature80 to 100°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 in/min
3. 0.39 in/min
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.