Makrolon® 1248 MAS068

About
MVR (300 °C/1.2 kg) 7.0 cm³/10 min; food contact quality; medium viscosity; impact modified; injection molding – melt temperature 280 – 320 °C; available in light colors only&&

Product Description
SupplierCovestro
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesHigh impact resistance,Food contact compliance,HB
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.20g/cm³ISO 1183
Apparent density0.64g/cm³ISO 60
Melt Flow Rate
300℃,1.20kg7.5g/10minISO 1133
Melt Volume Rate
300℃,1.2 kg7.00cm³/10minISO 1133
Shrinkage rate 
TD0.60 to 0.80%ISO 2577
MD0.60 to 0.80%ISO 2577
TD:2.0 mm0.80%ISO 294-4
MD:2.0 mm0.75%ISO 294-4
Water absorption rate
Saturation, 23 ℃0.40%ISO 62
Equilibrium, 23 ℃, 50% RH0.12%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 7391
-30 ℃, localized fracture60kJ/m²ISO 7391
23 ℃, localized fracture70kJ/m²ISO 7391
Charpy Unnotch Impact strength ISO 179/1eU
-60℃No Break ISO 179/1eU
-30℃No Break ISO 179/1eU
23℃No Break ISO 179/1eU
Impact strength of cantilever beam notch ISO 7391
-30 ℃, completely fractured30kJ/m²ISO 7391
23 ℃, localized fracture65kJ/m²ISO 7391
Multi axial instrumented impact energy ISO 6603-2
-30℃60.0JISO 6603-2
23℃55.0JISO 6603-2
Multi axial instrumented peak impact force ISO 6603-2
-30℃6100NISO 6603-2
23℃5200NISO 6603-2

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed124ISO 75-2/A
0.45 MPa, unannealed138ISO 75-2/B
Vicat Softening Temp 
B50147ISO 306
B120148ISO 306/B120
Ball pressure test
138℃Pass IEC 60695-10-2
Linear coefficient of thermal expansion
TD:23~55℃7.0E-51/℃ISO 11359-2
MD:23~55℃7.0E-51/℃ISO 11359-2
Thermal conductivity coefficient
23℃0.20W/m/KISO 8302

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+16ohmsIEC 60093
Volume resistivity
23℃1.0E+16ohms·cmIEC 60093
Dielectric strength
23 ℃,1 mm34kV/mmIEC 60243-1
Relative permittivity IEC 60250
23℃,100 Hz3.20 IEC 60250
23℃,1 MHz3.10 IEC 60250
Dissipation factor IEC 60250
23℃,100 Hz1.2E-3 IEC 60250
23℃,1 MHz0.012 IEC 60250
Compared to the leakage tracing index IEC 60112
Solution A225VIEC 60112
Solution B125VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
1.50 mmHB UL 94
Glowing wire flammability index IEC 60695-2-12
1.0 mm800IEC 60695-2-12
1.5 mm800IEC 60695-2-12
2.0 mm850IEC 60695-2-12
3.0 mm900IEC 60695-2-12
4.0 mm960IEC 60695-2-12
Igniting temperature of the hot wire IEC 60695-2-13
1.5 mm850IEC 60695-2-13
2 mm850IEC 60695-2-13
3 mm850IEC 60695-2-13
Extreme oxygen index30%ISO 4589-2
Burning rate
USFMVSS,> 1.00 mmpassed ISO 3795
Flash Ignition Temperature430ASTM D1929
Needle flame test IEC 60695-11-5
Method F:1.50 mm1.0minIEC 60695-11-5
Method F:2.00 mm1.0minIEC 60695-11-5
Method F:3.00 mm2.0minIEC 60695-11-5
Method K:2.00 mm0.1minIEC 60695-11-5
Method K:3.00 mm0.2minIEC 60695-11-5
Autoignition temperature540ASTM D1929

Supplementary informationNominal valueUnitTest method
Electrolytic corrosion
23℃A1 IEC 60426
ISO ShortnameISO 7391-PC,MP,(,,)-09-9 

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃2250MPaISO 527-1-2
tensile strength
Fracture, 23 ℃65.0MPaISO 527-2/50
Yield, 23 ℃61.0MPaISO 527-2/50
Tensile strain
Fracture, 23 ℃120%ISO 527-2/50
Yield, 23 ℃6.0%ISO 527-2/50
Nominal tensile fracture strain
23℃> 50%ISO 527-2/50
Bending modulus
23℃2250MPaISO 178
bending strength ISO 178
3.50% strain, 23 ℃68.0MPaISO 178
23℃88.0MPaISO 178
Bending strain6.8%ISO 178
Ball hardness108MPaISO 2039-1

Notes
1. Typical properties: these are not to be construed as specifications.
2. Pellets
3. 60x60x2 mm, 500 bar
4. 0.079 in/min
5. 2 mm/min
6. Based on ISO 179-1eA, 3 mm
7. Based on ISO 180-A, 3 mm
8. Cross-flow
9. Procedure A
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.