About |
---|
MVR (300 °C/1.2 kg) 7.0 cm³/10 min; structural foam; 5 % glass fiber reinforced; flame retardant; high viscosity; easy release; injection molding; available in natural (opaque) and opaque colors; in combination with an appropriate blowing agent for the production of structural foam moldings&& |
Product Description | |
---|---|
Supplier | Covestro |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Features | High Viscosity,Good stripping performance,Flame Characteristics,V-0,5VA |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.23 | g/cm³ | ISO 1183 |
Apparent density | 0.65 | g/cm³ | ISO 60 |
Melt Flow Rate | |||
300℃,1.20kg | 8.0 | g/10min | ISO 1133 |
Melt Volume Rate | |||
300℃,1.2 kg | 7.00 | cm³/10min | ISO 1133 |
Shrinkage rate | ISO 294-4 | ||
TD:2.0 mm | 0.55 | % | ISO 294-4 |
MD:2.0 mm | 0.70 | % | ISO 294-4 |
Water absorption rate | |||
Saturation, 23 ℃ | 0.30 | % | ISO 62 |
Equilibrium, 23 ℃, 50% RH | 0.10 | % | ISO 62 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | |||
23 ℃, completely fractured | 15 | kJ/m² | ISO 7391 |
Charpy Unnotch Impact strength | ISO 179/1eU | ||
-60 ℃, completely fractured | 90 | kJ/m² | ISO 179/1eU |
-30 ℃, completely fractured | 140 | kJ/m² | ISO 179/1eU |
-20 ℃, completely fractured | 25 | kJ/m² | ISO 179/1eU |
-20 ℃, completely fractured | 160 | kJ/m² | ISO 179/1eU |
23 ℃, completely fractured | 190 | kJ/m² | ISO 179/1eU |
23 ℃, completely fractured | 25 | kJ/m² | ISO 179/1eU |
Impact strength of cantilever beam notch | |||
23 ℃, completely fractured | 12 | kJ/m² | ISO 7391 |
Multi axial instrumented impact energy | ISO 6603-2 | ||
-30℃ | 25.0 | J | ISO 6603-2 |
23℃ | 30.0 | J | ISO 6603-2 |
Multi axial instrumented peak impact force | ISO 6603-2 | ||
-30℃ | 4900 | N | ISO 6603-2 |
23℃ | 4300 | N | ISO 6603-2 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | ISO 75-2/B | ||
0.45 MPa, unannealed | 140 | ℃ | ISO 75-2/B |
0.45 MPa, unannealed, 6.0 mm | 133 | ℃ | ISO 75-2/B |
Hot deformation temperature | ISO 75-2/A | ||
1.8 MPa, unannealed | 130 | ℃ | ISO 75-2/A |
1.8 MPa, unannealed, 6.00 mm | 125 | ℃ | ISO 75-2/A |
Vicat Softening Temp | |||
B50 | ISO 306/B50 | ||
B50 | 132 | ℃ | ISO 306/B50 |
B50 | 143 | ℃ | ISO 306/B50 |
Ball pressure test | |||
136℃ | Pass | IEC 60695-10-2 | |
Linear coefficient of thermal expansion | |||
TD:23~55℃ | 7.0E-5 | 1/℃ | ISO 11359-2 |
MD:23~55℃ | 5.5E-5 | 1/℃ | ISO 11359-2 |
Thermal conductivity coefficient | |||
23℃ | 0.22 | W/m/K | ISO 8302 |
Relative temperature index | |||
Electrical performance, 3.00 mm | 80.0 | ℃ | UL 746 |
Strength mechanical performance, 3.00 mm | 80.0 | ℃ | UL 746 |
Impact mechanical performance, 3.00 mm | 80.0 | ℃ | UL 746 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Surface resistivity | 1.0E+16 | ohms | IEC 60093 |
Volume resistivity | |||
23℃ | 1.0E+16 | ohms·cm | IEC 60093 |
Dielectric strength | |||
23 ℃,1 mm | 34 | kV/mm | IEC 60243-1 |
Relative permittivity | IEC 60250 | ||
23℃,100 Hz | 3.10 | IEC 60250 | |
23℃,1 MHz | 3.00 | IEC 60250 | |
Dissipation factor | IEC 60250 | ||
23℃,100 Hz | 8.0E-4 | IEC 60250 | |
23℃,1 MHz | 9.0E-3 | IEC 60250 | |
Compared to the leakage tracing index | IEC 60112 | ||
Solution A | 175 | V | IEC 60112 |
Solution B | 125 | V | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | UL 94 | ||
3.00 mm, gray | V-0 | UL 94 | |
6.00 mm, gray | V-0 5VA | UL 94 | |
5.00 mm, gray | 5VA | UL 94 | |
Glowing wire flammability index | IEC 60695-2-12 | ||
1.0 mm | 850 | ℃ | IEC 60695-2-12 |
1.5 mm | 960 | ℃ | IEC 60695-2-12 |
3.0 mm | 960 | ℃ | IEC 60695-2-12 |
4.0 mm | 960 | ℃ | IEC 60695-2-12 |
Igniting temperature of the hot wire | IEC 60695-2-13 | ||
0.8 mm | 825 | ℃ | IEC 60695-2-13 |
1.5 mm | 825 | ℃ | IEC 60695-2-13 |
3 mm | 825 | ℃ | IEC 60695-2-13 |
Extreme oxygen index | 32 | % | ISO 4589-2 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
ISO Shortname | ISO 7391-PC,MFR,(,,)-09-9,GF5 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | |||
23℃ | 2900 | MPa | ISO 527-1-2 |
23℃,6 mm | 1800 | MPa | ISO 527-2/25 |
tensile strength | ISO 527-2/5 | ||
Yield, 23 ℃ | 62.0 | MPa | ISO 527-2/5 |
Fracture, 23 ℃, 6 mm | 35.0 | MPa | ISO 527-2/5 |
Fracture, 23 ℃ | 60.0 | MPa | ISO 527-2/5 |
Tensile strain | ISO 527-2/5 | ||
Yield, 23 ℃ | 4.7 | % | ISO 527-2/5 |
Fracture, 23 ℃, 6 mm | 6.0 | % | ISO 527-2/5 |
Fracture, 23 ℃ | 20 | % | ISO 527-2/5 |
Bending modulus | ISO 178 | ||
23℃,6 mm | 1800 | MPa | ISO 178 |
23℃ | 2900 | MPa | ISO 178 |
bending strength | ISO 178 | ||
3.50% strain, 23 ℃ | 85.0 | MPa | ISO 178 |
3.50% strain, 23 ℃, 6.00 mm | 55.0 | MPa | ISO 178 |
23℃ | 100 | MPa | ISO 178 |
23℃,6 mm | 55.0 | MPa | ISO 178 |
Bending strain | ISO 178 | ||
23℃ | 6.0 | % | ISO 178 |
23℃,6.00 mm | 5.0 | % | ISO 178 |
Ball hardness | ISO 2039-1 | ||
— | 119 | MPa | ISO 2039-1 |
6.00 mm | 50.0 | MPa | ISO 2039-1 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. Pellets |
3. 60x60x2 mm, 500 bar |
4. Foamed; density in the foamed state: 900 to 1000 kg/m³ |
5. 0.079 in/min |
6. 2 mm/min |
7. 2 mm/min, Foamed; density in the foamed state: 900 to 1000 kg/m³ |
8. Based on ISO 179-1eA, 3 mm |
9. Foamed 6.0 mm; density in the foamed state: 900 to 1000 kg/m³ |
10. Based on ISO 180-A, 3 mm |
11. 6.0 mm, Foamed; density in the foamed state: 900 to 1000 kg/m³ |
12. Cross-flow |
13. Procedure A |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |