Maxxam™ FR QD 813.Y001-1000 RoHS

About
Maxxam™ FR flame-retardant polyolefin compounds and masterbatches meet stringent flammability performance requirements defined by industry agencies, including Underwriters Laboratories UL 94 V-2, V-0, and 5VA performance ratings. In addition, many compounds in the Maxxam FR portfolio offer elevated Relative Thermal Index (RTI) ratings.&&

Product Description
SupplierPolyone
GenericPP not specified
Material StatusCommercial: Active
FeaturesHigh impact resistance,Flame Characteristics,V-0
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.46g/cm³ASTM D792
Specific volume0.715cm³/gASTM D792
Melt Flow Rate
230℃,2.16kg4.0g/10minASTM D1238
Shrinkage rate
MD0.10 to 0.30%ASTM D955
Outdoor applicability
wholef1 UL 746C

MECHANICALNominal valueUnitTest method
tensile strength
yield44.8MPaASTM D638
Tensile strain
fracture7.0%ASTM D638
Bending modulus4690MPaASTM D790
bending strength68.9MPaASTM D790

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
23 ℃, 3.2mm, injection molding190J/mASTM D256-A

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed, 3.2 mm150ASTM D648

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.50 mm, all colorsV-0 UL 94
2.00 mm, all colorsV-0 5VA UL 94
3.00 mm, all colorsV-0 5VA UL 94

Notes
1. EM1002639160 QD-813.Y001-1000 RoHS replaced this grade.
2. Typical properties: these are not to be construed as specifications.
3. Procedure A
4. Type I, 0.20 in/min
5. Type I, 2.0 in/min
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.