Minlon® 73GM40 NC010

About
40% Mineral/Glass Reinforced Polyamide 6&&

Product Description
SupplierDuPont
GenericPA6
Material StatusCommercial: Active
FeaturesElectroplating,Heat Stabilized
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.46g/cm³ISO 1183
Shrinkage rate
MD:2.0 mm0.50%ISO 294-4
TD:2.0 mm0.70%ISO 294-4
Water absorption rate
23℃,24hr,2.00 mm5.60%ISO 62
23℃,50% RH,2.00 mm1.60%ISO 62

MECHANICALNominal valueUnitTest method
tensile strength
23℃140MPaISO 527-2
Tensile strain
Fracture, 23 ℃3%ISO 527-2
Tensile modulus
23℃8300MPaISO 527-2

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed215ISO 75-2/Bf
1.8 MPa, annealed195ISO 75-2/Af
Melting temperature221ISO 11357-3
Glass transition temperature70ISO 11357-2
Vicat Softening Temp
B50210ISO 306
Linear coefficient of thermal expansion
MD4.1E-51/℃ISO 11359-2
TD7.7E-51/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Volumetric resistance>1.0E+15Ω.cmIEC 60093
Insulation strength
33KV/mmIEC 60243-1
Dissipation factor
23℃0.013100 HzIEC 60250
23℃3.8E-31 MHzIEC 60250
Compared to the leakage tracing index500VIEC 60112

IMPACTNominal valueUnitTest method
Charpy Unnotch Impact strength
23℃60kJ/m²ISO 179/1eU
-30℃50kJ/m²ISO 179/1eU
Charpy Notched Impact Strength
23℃7kJ/m²ISO 179/1eA
-30℃5.50kJ/m²ISO 179/1eA
Impact strength of cantilever beam notch
23℃5.50kJ/m²ISO 180-1A
-30℃4.00kJ/m²ISO 180-1A

Notes
1. Typical properties: these are not to be construed as specifications.
2. 10°C/min
3. FMVSS 302
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.