| About |
|---|
| PPE+PS blend. Unfilled. UL94 HB rated. Low water absorption. Hydrolytic stability. Dimensional stability.&& |
| Product Description | |
|---|---|
| Supplier | SABIC |
| Generic | PPO(PPE)+PS |
| Material Status | Commercial: Active |
| Features | Excellent Processability,Good Dimensional Stability,Hydrolysis stability,Low or no water absorption,High Heat Resistance,Moisture resistance |
| Availabilitys | North America,Asia Pacific,Europe |
| Process Methods | Injection Molding |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.06 | g/cm³ | ASTM D792 |
| Melt Flow Rate | |||
| 280℃,5.0kg | 14 | g/10min | ASTM D1238 |
| Shrinkage rate | |||
| MD:3.2 mm | 0.50 to 0.70 | % | Internal Method |
| Water absorption rate | |||
| 24hr | 0.10 | % | ASTM D570 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179/2C | ||
| -30℃ | 10 | kJ/m² | ISO 179/2C |
| 23℃ | 17 | kJ/m² | ISO 179/2C |
| Impact strength of cantilever beam notch | ASTM D256 | ||
| -40℃ | 130 | J/m | ASTM D256 |
| -30℃ | 180 | J/m | ASTM D256 |
| 23℃ | 230 | J/m | ASTM D256 |
| Impact strength of cantilever beam notch | ISO 180/1A | ||
| -30℃ | 10 | kJ/m² | ISO 180-1A |
| 23℃ | 18 | kJ/m² | ISO 180-1A |
| Dart impact equipped with measuring instruments | |||
| 23 ℃, total energy | 40.0 | J | ASTM D3763 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | ASTM D648 | ||
| 1.8 MPa, unannealed, 100 mm span | 107 | ℃ | ISO 75-2/Ae |
| 0.45 MPa, unannealed, 100 mm span | 122 | ℃ | ISO 75-2/Be |
| 0.45 MPa, unannealed, 3.2 mm | 120 | ℃ | ASTM D648 |
| 0.45 MPa, unannealed, 6.4 mm | 121 | ℃ | ASTM D648 |
| 1.8 MPa, unannealed, 3.2 mm | 105 | ℃ | ASTM D648 |
| 1.8 MPa, unannealed, 6.4 mm | 113 | ℃ | ASTM D648 |
| Vicat Softening Temp | |||
| B50 | 125 | ℃ | ISO 306 |
| B120 | 128 | ℃ | ISO 306/B120 |
| Linear coefficient of thermal expansion | |||
| MD:0~100℃ | 7.4E-5 | 1/℃ | ASTM E831 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | 2290 | MPa | ASTM D638 |
| Tensile modulus | 2350 | MPa | ISO 527-1-2 |
| tensile strength | |||
| fracture | 43.0 | MPa | ISO 527-2 |
| fracture | 44.0 | MPa | ASTM D638 |
| yield | 47.0 | MPa | ISO 527-2 |
| yield | 49.6 | MPa | ASTM D638 |
| Tensile strain | |||
| fracture | 27 | % | ASTM D638 |
| fracture | 43 | % | ISO 527-2 |
| yield | 3.0 | % | ASTM D638 |
| yield | 2.9 | % | ISO 527-2 |
| Bending modulus | ASTM D790 | ||
| 50 mm span | 2550 | MPa | ASTM D790 |
| 100 mm span | 2240 | MPa | ASTM D790 |
| Bending modulus | 2400 | MPa | ISO 178 |
| bending strength | 78.0 | MPa | ISO 178 |
| bending strength | ASTM D790 | ||
| Yield, 50 mm span | 80.0 | MPa | ASTM D790 |
| Yield, 100 mm span | 75.8 | MPa | ASTM D790 |
| Rockwell hardness | |||
| R-level | 114 | ASTM D785 |
| Process Conditions | |||
|---|---|---|---|
| injection | Nominal value | Unit | Test method |
| Drying temperature | 104 to 110 | °C | |
| Drying time | 3.0 to 4.0 | hr | |
| Drying time, maximum | 8.0 | hr | |
| Recommended maximum moisture content | 0.020 | % | |
| Recommended injection volume | 30 to 70 | % | |
| Barrel rear temperature | 243 to 293 | °C | |
| Barrel middle temperature | 254 to 299 | °C | |
| Barrel front temperature | 266 to 304 | °C | |
| Nozzle temperature | 277 to 304 | °C | |
| Processing (melt) temperature | 277 to 304 | °C | |
| Mold temperature | 71 to 99 | °C | |
| Back pressure | 0.345 to 0.689 | MPa | |
| Screw speed | 20 to 100 | rpm | |
| Vent depth | 0.038 to 0.051 | mm | |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 2. 0.20 in/min |
| 3. Type I, 2.0 in/min |
| 4. Type I, 0.20 in/min |
| 5. 0.10 in/min |
| 6. 0.051 in/min |
| 7. 80*10*4 mm |
| 8. 120*10*4 mm |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |