About |
---|
PPE+PS blend. Unfilled. Good balance of flow/heat/impact. Dimensional stability. Paint adhesion. Suitable for the automotive interior market: HVAC housings, radio components. MS-DB424, WSB-M4D844-A9, GMP.PPE.007.&& |
Product Description | |
---|---|
Supplier | SABIC |
Generic | PPO(PPE)+PS |
Material Status | Commercial: Active |
Features | High impact resistance,Good Dimensional Stability,Good liquidity,High Heat Resistance |
Availabilitys | North America |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.05 | g/cm³ | ASTM D792 |
Melt Flow Rate | |||
280℃,5.0kg | 15 | g/10min | ASTM D1238 |
Melt Volume Rate | |||
280℃,5 kg | 15.0 | cm³/10min | ISO 1133 |
Shrinkage rate | |||
MD:3.2 mm | 0.50 to 0.70 | % | Internal Method |
Water absorption rate | |||
24hr | 0.20 | % | ASTM D570 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | |||
— | 1900 | MPa | ASTM D638 |
— | 2050 | MPa | ISO 527-1-2 |
tensile strength | |||
yield | 43.0 | MPa | ASTM D638 |
yield | 42.0 | MPa | ISO 527-2 |
fracture | 40.0 | MPa | ASTM D638 |
Tensile strain | |||
yield | 3.0 | % | ASTM D638 |
yield | 2.8 | % | ISO 527-2 |
fracture | 65 | % | ASTM D638 |
fracture | 60 | % | ISO 527-2 |
Bending modulus | |||
50 mm span | 2100 | MPa | ASTM D790 |
100 mm span | 2000 | MPa | ASTM D790 |
— | 2100 | MPa | ISO 178 |
bending strength | |||
— | 65.0 | MPa | ISO 178 |
Yield, 50 mm span | 67.0 | MPa | ASTM D790 |
Yield, 100 mm span | 66.0 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | |||
-30℃ | 19 | kJ/m² | |
23℃ | 33 | kJ/m² | |
Impact strength of cantilever beam notch | |||
-30℃ | 250 | J/m | ASTM D256 |
23℃ | 450 | J/m | ASTM D256 |
-30℃ | 15 | kJ/m² | ISO 180-1A |
23℃ | 33 | kJ/m² | ISO 180-1A |
Dart impact equipped with measuring instruments | |||
-30℃,Energy at Peak | 24.0 | J | |
23℃,Energy at Peak | 36.0 | J | |
23℃,Total Energy | 42.0 | J |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
0.45 MPa, unannealed, 3.2 mm | 124 | ℃ | ASTM D648 |
0.45 MPa, unannealed, 4.0 mm, 64 mm span | 126 | ℃ | ISO 75-2/Bf |
1.8 MPa, unannealed, 3.2 mm | 106 | ℃ | ASTM D648 |
1.8 MPa, unannealed, 6.4 mm | 115 | ℃ | ASTM D648 |
1.8 MPa, unannealed, 4.0 mm, 64 mm span | 110 | ℃ | ISO 75-2/Af |
Vicat Softening Temp | |||
B50 | 119 | ℃ | ISO 306 |
B120 | 123 | ℃ | ISO 306/B120 |
Linear coefficient of thermal expansion | |||
MD:0~100℃ | 1.2E-4 | 1/℃ | ASTM E831 |
Relative temperature index | 50.0 | ℃ | UL 746 |
Electrical performance | 50.0 | ℃ | UL 746 |
Impact mechanical performance | 50.0 | ℃ | UL 746 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
1.50 mm | HB | UL 94 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 95 to 105 | °C | |
Drying time | 3.0 to 4.0 | hr | |
Recommended maximum moisture content | 0.020 | % | |
Recommended injection volume | 30 to 70 | % | |
Barrel rear temperature | 230 to 280 | °C | |
Barrel middle temperature | 245 to 290 | °C | |
Barrel front temperature | 255 to 295 | °C | |
Nozzle temperature | 265 to 295 | °C | |
Processing (melt) temperature | 265 to 295 | °C | |
Mold temperature | 65 to 95 | °C | |
Back pressure | 0.300 to 0.700 | MPa | |
Screw speed | 20 to 100 | rpm | |
Vent depth | 0.038 to 0.051 | mm |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 0.20 in/min |
3. Type I, 2.0 in/min |
4. 0.10 in/min |
5. 0.051 in/min |
6. 80*10*4 mm |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |