PEEK-OPTIMA® Image Contrast (Low radiopacity)

About
PEEK-OPTIMA® image contrast compounds, from Invibio® Biomaterial Solutions, offer implant manufacturers all the benefits of PEEK-OPTIMA polymer, now with tailored radiopacity. These compounds comprise an image contrast additive at specified levels, providing a broad contrast range for optimal visualization with x-ray, CT and MRI imaging modalities. PEEK-OPTIMA image contrast grades are safe, biocompatible materials intended for implantable medical and pharmaceutical devices and applications requiring blood, bone or tissue contact of more than 30 days. These compounds provide a unique combination of features and benefits, including: Tailored radiopacity allows implant visibility to be optimized PEEK-OPTIMA polymer provides a superior combination of strength, stiffness and toughness, even after sterilization Biocompatibility ensures safe, long term implantation Processing methods allow broad design and manufacturing flexibility US FDA Drug and Device Master files can assist with regulatory requirements Unlike metals, PEEK-OPTIMA image contrast grades provide the possibility of tailoring the visibility of an implant to suit a particular application. It is therefore possible to achieve an appropriate balance of implant, bone and tissue visualization without artifacts or scatter. Available in a range of viscosities (standard, medium and low), PEEK-OPTIMA image contrast grades can be processed by conventional methods, including injection molding and extrusion, and can be machined, allowing medical device manufacturers broad design and manufacturing flexibility. Extensive testing of PEEK-OPTIMA compounds to ISO 10993 standards demonstrated no evidence of cytotoxicity, systemic toxicity or irritation. Results have been lodged with the US FDA and can reduce the time and expense of the approval process.&&

Product Description
GenericPEEK
Material StatusCommercial: Active
FeaturesGood Rigidity,Good flexibility,High purity,Biocompatible,Blocking,Low toxicity
AvailabilitysNorth America,Europe
Process MethodsExtrusion

Technical Data
PHYSICALNominal valueUnitTest method
Density1.36g/cm³ISO 1183

MECHANICALNominal valueUnitTest method
tensile strength
yield95.0MPaISO 527-2
Tensile strain
fracture20%ISO 527-2
Bending modulus3800MPaISO 178
bending strength150MPaISO 178

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch7.0kJ/m²ISO 180

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.