PENTAMID AB S GV50 H black

About
Low viscosity, heat stabilised polyamide 66+6, 50% glass fiber reinforced&&

Product Description
GenericPA66/6
Material StatusCommercial: Active
FeaturesLow Viscosity,Heat Stabilized,HB
AvailabilitysNorth America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.56g/cm³ISO 1183
Shrinkage rate ISO 294-4
TD0.40%ISO 294-4
MD0.20%ISO 294-4
Water absorption rate ISO 62
Saturation, 23 ℃4.8%ISO 62
Equilibrium, 23 ℃, 50% RH1.5%ISO 62
Viscosity number125cm³/gISO 307

MECHANICALNominal valueUnitTest method
Tensile modulus16500MPaISO 527-1-2
tensile strength
fracture225MPaISO 527-2/5
Tensile strain
fracture2.5%ISO 527-2/5

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃15kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength
23℃85kJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed250ISO 75-2/A
Melting temperature255ISO 11357-3

FLAME CHARACTERISTICSNominal valueUnitTest method
1.60 mmHB UL 94

Supplementary informationNominal valueUnitTest method
ISO ShortnamePA66+PA6, MHRC, 12-160, GF50 ISO 1874

Process Conditions
injectionNominal valueUnitTest method
Drying temperature80°C
Drying time3.0hr
Recommended maximum moisture content0.030 to 0.11%
Proposed maximum recycled material ratio20%
Barrel rear temperature280 to 300°C
Barrel middle temperature285 to 310°C
Barrel front temperature290 to 300°C
Processing (melt) temperature280 to 310°C
Mold temperature60 to 100°C
Injection pressure90.0MPa
Screw length to diameter ratio18.0:1.0 to 22.0:1.0 
Screw compression ratio2.2:1.0 to 2.8:1.0 

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.