About |
---|
Moisture-curable Low Smoke Zero-Halogen (LSZH) insulation compound for low voltage building wire applications (UL styles XHHW-2, RHW-2, RHH, SIS). PEXIDAN ® HF X/T is a unique low smoke halogen-free flame retardant 90°C wet-rated XL-insulation system curable by moisture. It consists of a silane pre-grafted base compound SX-0651 and a catalyst masterbatch CM540U or CM540U/1. Mixed and extruded in the proper proportions (95:5), the two components result in a material that is crosslinkable by exposure to 90°C hot water. PEXIDAN ® HF X/T is REACH and RoHS-compliant and is UL 2885 certified to bear the Halogen Free “HF” designation. PEXIDAN ® HF X/T is UL-bulletinized and wire made with this insulation system may be marked as Oil Resistant “PR I” and “PR II”, Gas & Oil Resistant “GR I” and “GR II”, and “-40C”. This compound will meet 105°C dry rating.&& |
Product Description | |
---|---|
Generic | 3D打印材料 |
Material Status | Commercial: Active |
Features | Low smoke,Crosslinked,Halogen free,Grease resistance,Gasoline resistance |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Process Methods | Extrusion |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.27 | g/cm³ | ASTM D792 |
The degree of cross combination | 77 | % | ASTM D2765 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | |||
yield | 14.6 | MPa | |
fracture | 17.0 | MPa | |
fracture | 12.8 | MPa | |
fracture | 12.4 | MPa | |
fracture | 15.2 | MPa | |
Tensile strain | |||
fracture | 400 | % | UL 1581 |
fracture | 240 | % | UL 1581 |
fracture | 270 | % | UL 1581 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
deformation | < 15.0 | UL 1581 | |
Low temperature bending | |||
-40℃ | Pass | UL 1581 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Dielectric constant | |||
100 MHz | 2.98 | ASTM D150 | |
500 MHz | 3.31 | ASTM D150 | |
90 ℃,60 Hz | 3.37 | UL 1581 | |
Dissipation factor | |||
100 MHz | 2.7E-3 | ||
500 MHz | 5.2E-3 | ||
breakdown voltage | |||
Initial | < 39000 | V | |
Retention after glancing impact | 81 | % | |
insulation resistance | |||
15℃ | 9000 | Mohms/1000 ft | |
After 12 weeks:90℃ | 110 | Mohms/1000 ft | |
Initial:90℃ | 1400 | Mohms/1000 ft |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Extreme oxygen index | 34 | % | ASTM D2863 |
Flame Resistance | |||
FT2 | Pass | ||
VW-1 | Pass (#10 up) | ||
Smoke density | |||
Flaming | |||
Non-flaming |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
Conductivity | 0.128 | µS/mm | |
Flame retardant level | |||
pH | 5.72 | ||
> 635029 | g | UL 1581 | |
150℃ | < 35 | % |
Process Conditions | |||
---|---|---|---|
Extrusion | Nominal value | Unit | Test method |
Barrel 1 zone temperature | 154 to 171 | °C | |
Barrel 2 zone temperature | 154 to 171 | °C | |
Barrel 3 zone temperature | 154 to 171 | °C | |
Barrel 4 zone temperature | 154 to 171 | °C | |
Barrel 5 zone temperature | 177 | °C | |
Nozzle temperature | 179 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 23°C |
3. After 96 hours oil @100°C |
4. after thermal ageing (7d @121°C) |
5. After 60 day oil @75°C |
6. 0.2 N/mm 2 load |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |