| About |
|---|
| UV transmitting PLEXIGLAS® GS is a kind of cast acrylic (= polymethylmethacrylate, PMMA) specially developed for tanning beds, with high UV (ultraviolet) transmission and UV resistance. UV transmitting PLEXIGLAS® GS has a perfectly coherent surface, whether in its smooth or satin-finished version. It always feels pleasantly warm to the skin and is hygienic. It is therefore ideally suited for use in both cosmetic and therapeutic UV appliances. The material is particularly resistant to extremes of climate, i. e. also ideal for applications exposed to heat and humidity in addition to UV radiation. UV transmitting PLEXIGLAS® GS exhibits high mechanical strength at low weight. Clear 2890 with specially adjusted UV transmission for special applications.&& |
| Product Description | |
|---|---|
| Supplier | ROHM |
| Generic | PMMA |
| Material Status | Commercial: Active |
| Features | Good Rigidity,Weather resistance is good,Good surface appearance,Antifreeze,High Heat Resistance,Moisture resistance,Low molecular weight,HB |
| Availabilitys | Europe |
| Process Methods | Thermo forming |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.19 | g/cm³ | ISO 1183 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | > 2500 | MPa | ISO 527-2 |
| tensile strength | |||
| 3 mm | > 60.0 | MPa | ISO 527-2 |
| Tensile strain | |||
| Fracture, 3 mm | > 5.0 | % | ISO 527-2 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Vicat Softening Temp | 100 | ℃ | ISO 306/B |
| Linear coefficient of thermal expansion | |||
| MD:0~50℃ | 7.0E-4 | 1/℃ | ISO 11359-2 |
| Thermal conductivity coefficient | 0.19 | W/m/K | DIN 52612 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Flame retardant level | HB | UL 94 | |
| Flame retardant level | |||
| — | Class 3 | BS 476 Part 7 | |
| — | M4 | NF P 92501 | |
| inflammable | B2 | DIN 4102 |
| optical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Transmittance | DIN 5036-3 | ||
| — | > 90.0 | % | DIN 5036-3 |
| 3000 µm | > 60.0 | % | DIN 5036-3 |
| 8000 µm | > 25.0 | % | DIN 5036-3 |
| Notes |
|---|
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |