About |
---|
EVA copolymer ALCUDIA® PA-540 is suitable for injection moulding and recommended for those applications where flexibility and toughness are required. It contains antioxidant additives. TYPICAL APPLICATIONS Injection moulding. Release agents containing silicone must be avoided. Rotational moulding Recommended melt temperature below 200°C to avoid the decomposition of the polymer. Processing conditions should be optimised for each production line.&& |
Product Description | |
---|---|
Supplier | REPSOL |
Generic | EVA |
Material Status | Commercial: Active |
Features | Good flexibility,Food contact compliance,Inoxidizability |
Availabilitys | North America,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 0.937 | g/cm³ | ISO 1183 |
Melt Flow Rate | |||
190℃,2.16kg | 10 | g/10min | ISO 1133 |
ESCR(Environmental Stress Cracking Resistance) | |||
F50 | 300 | hr | ASTM D1693 |
Vinyl acetate content | 18.0 | wt% |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Vicat Softening Temp | 59.0 | ℃ | ISO 306/A |
Melting temperature | 89.0 | ℃ |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Shore hardness | |||
Shaw’s A | 90 | ||
Shaw’s D | 36 | ||
tensile strength | |||
fracture | 16.0 | MPa | ISO 527-2 |
Tensile strain | |||
fracture | 700 | % | ISO 527-2 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Processing (melt) temperature | 200 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |