RTP 900 P-1700

About
UL94&&

Product Description
GenericPSU
Material StatusCommercial: Negative
FeaturesHB,V-0
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.24g/cm³ASTM D792
Shrinkage rate
MD:3.2 mm0.50 to 0.90%ASTM D955
Water absorption rate
23℃,24hr0.30%ASTM D570
water content0.15%

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
3.2mm69J/mASTM D256
Notched impact strength of cantilever beam
3.2 mm2100J/mASTM D4812

THERMALNominal valueUnitTest method
Hot deformation temperature ASTM D648
0.45 MPa, unannealed181ASTM D648
1.8 MPa, unannealed174ASTM D648

Electrical performanceNominal valueUnitTest method
Volume resistivity> 1.0E+16ohms·cmASTM D257
Dielectric strength
In oil17kV/mmASTM D149
Dielectric constant
1 MHz3.00 ASTM D150
Dissipation factor
1 MHz3.0E-3 ASTM D150
Arc resistance122secASTM D495

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.50 mmHB UL 94
4.40 mmV-0 UL 94

MECHANICALNominal valueUnitTest method
Rockwell hardness
R-level120 ASTM D785
Tensile modulus2480MPaASTM D638
tensile strength68.9MPaASTM D638
Tensile strain
yield> 75%ASTM D638
Bending modulus2690MPaASTM D790
bending strength103MPaASTM D790

Process Conditions
injectionNominal valueUnitTest method
Drying temperature135°C
Drying time4.0hr
Dew Point-32°C
Processing (melt) temperature332 to 371°C
Mold temperature93 to 149°C
Injection pressure68.9 to 124MPa

Notes
1. Typical properties: these are not to be construed as specifications.
2. Method A (Short-Time)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.