SD POLYCA™ 875G10

About
Silicone-based Flame Retardant / Glass Fiber Reinforced Grades&&

Product Description
SupplierSumitomo
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesExcellent Processability,Hydrolysis stability,Flame Characteristics,Heat Resistance, Good,Heat Stabilized
AvailabilitysAsia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density1.27g/cm³ISO 1183
Shrinkage rate
MD0.30 to 0.50%
TD0.40 to 0.60%
Water absorption rate
23℃,24hr0.15%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus4100MPaISO 527-2
tensile strength
73.0MPaASTM D638
85.0MPaISO 527-2
Tensile strain
fracture4.0%ASTM D638
fracture5.0%ISO 527-2
Bending modulus
3630MPaASTM D790
3600MPaISO 178
bending strength
111MPaASTM D790
120MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength10kJ/m²ISO 179
Charpy Unnotch Impact strength50kJ/m²ISO 179
Impact strength of cantilever beam notch
23℃78J/mASTM D256

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed141ASTM D648
1.8 MPa, unannealed140ISO 75-2/A
Linear coefficient of thermal expansion
MD4.0E-51/℃
TD6.5E-51/℃

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
1.50 mmV-0 
3.00 mmV-0 

Notes
1. Typical properties: these are not to be construed as specifications.
2. 4mmt
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.