About |
---|
Silicone-based Flame Retardant / Glass Fiber Reinforced Grades&& |
Product Description | |
---|---|
Supplier | Sumitomo |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Features | Excellent Processability,Hydrolysis stability,Flame Characteristics,Heat Resistance, Good,Heat Stabilized |
Availabilitys | Asia Pacific |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.34 | g/cm³ | ISO 1183 |
Shrinkage rate | |||
MD | 0.30 to 0.50 | % | |
TD | 0.40 to 0.60 | % | |
Water absorption rate | |||
23℃,24hr | 0.15 | % | ISO 62 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 6300 | MPa | ISO 527-2 |
tensile strength | |||
— | 97.0 | MPa | ASTM D638 |
— | 110 | MPa | ISO 527-2 |
Tensile strain | |||
fracture | 4.0 | % | ASTM D638 |
Bending modulus | |||
— | 5700 | MPa | ASTM D790 |
— | 5400 | MPa | ISO 178 |
bending strength | 130 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | 15 | kJ/m² | ISO 179 |
Charpy Unnotch Impact strength | 45 | kJ/m² | ISO 179 |
Impact strength of cantilever beam notch | |||
23℃ | 88 | J/m | ASTM D256 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 144 | ℃ | ASTM D648 |
1.8 MPa, unannealed | 143 | ℃ | ISO 75-2/A |
Linear coefficient of thermal expansion | |||
MD | 3.0E-5 | 1/℃ | |
TD | 6.0E-5 | 1/℃ |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
1.50 mm | V-0 | ||
3.00 mm | V-0 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 4mmt |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |