SI-LINK™ DFDA-6451 NT

About
SI-LINK™ Crosslinkable Polyethylene DFDA-6451 Natural with a density of 0.922, and a melt index of 1.5, is a silane-ethylene copolymer for use in medium voltage power cable applications. DFDA-6451 Natural may be crosslinked after it is extruded with DFDB-5480 Natural catalyst masterbatch by allowing moisture to diffuse into the insulation. Specifications SI-Link DFDA-6451 NT / SI-Link DFDB 5480 in combination, can be used as the insulation of XLPE medium voltage cables. DFDA-6451 NT/DFDB 5480 NT, when processed using sound extrusion and crosslinking conditions, meet typical medium voltage requirements as outlined in IEC 60502.&&

Product Description
SupplierDOW
GenericPE copolymerization
Material StatusCommercial: Active
AvailabilitysAfrica & Middle East ,North America,Asia Pacific
Process MethodsProfile extrusion

Technical Data
PHYSICALNominal valueUnitTest method
Density0.922g/cm³ASTM D1505
Melt Flow Rate
190℃,2.16kg1.5g/10minASTM D1238

MECHANICALNominal valueUnitTest method
tensile strength16.5MPaASTM D638
Tensile strain
fracture350%ASTM D638

Aging performanceNominal valueUnitTest method
Tensile strength retention rate
7 days,121℃90%ASTM D638
Elongation retention rate
7 days,121℃95%ASTM D638

THERMALNominal valueUnitTest method
High temperature creep100%ICEA T-28-562

Electrical performanceNominal valueUnitTest method
Dielectric constant2.30 ASTM D150
power factor2.50E-4radASTM D150

Process Conditions
ExtrusionNominal valueUnitTest method
Drying temperature60 to 71°C
Drying time4.0 to 6.0hr
Melt temperature149 to 232°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. 20 in/min
3. Cured 2.5 hours in 90°C water, 30 mil wall
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.