Stanyl® TS350

About
Unreinforced, Flame Retardant&&

Product Description
SupplierDSM
GenericPA 46
Material StatusCommercial: Active
FeaturesFlame Characteristics
AvailabilitysAsia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density1430kg/m³ISO 1183
Moisture Absorption2.35%Sim. to ISO 62
Mold Shrinkage
Parallel1.5%Sim. to ISO 294-4
Vertical normal1.5%Sim. to ISO 294-4

MECHANICALNominal valueUnitTest method
Tensile Modulus3400MPaISO 527-1/-2
Tensile Stress
Yield yld80MPaISO 527-1/-2
Tensile Strain
Broken BRK7%ISO 527-1/-2
Flexural Modulus3200MPaISO 178
Flexural Strength130MPaISO 178

IMPACTNominal valueUnitTest method
Izod Notched Impact strength
23°C4KJ/m²ISO 179/1A
-30°C3KJ/m²ISO 179/1A

THERMALNominal valueUnitTest method
Melting temperature
10°C/min295ISO 11357-1/-3
Hot deformation temperature HDT
Unannealed, 1.80MPa190ISO 75-1/-2
Coeff. of linear thermal expansion
Parallel8×10-5/℃ISO 11357-1/-2
Vertical normal9×10-5/℃ISO 11357-1/-2

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame Class Rating
1.5mmV-0calssIEC 60695-11-10
3.0mmV-0calssIEC 60695-11-10

ELECTRICALNominal valueUnitTest method
Volume Resistance1E+13ohm·mIEC 62631-3-1
Dielectric Strength30kV/mmIEC 60243-1
Compared Tracking Index225VIEC 60112
Dielectric Constant
100 Hz3.8IEC 62631-2-1
1 MHz3.5IEC 62631-2-1

Notes
1. Typical properties: these are not to be construed as specifications.
2. 10°C/min
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.