Stat-Rite® M2809

About
Stat-Rite® M2809 is a static dissipative acrylic alloy. Stat-Rite® M2809 utilizes the patented Stat-Rite® inherently dissipative polymer (IDP) alloy system to provide clean, permanent ESD protection. Stat-Rite® IDP alloys provide consistent static dissipation even when injection molded into components. FEATURES Permanently static dissipative Humidity independent Clean: low out-gassing, low extractable ionics Durable: can be used for years APPLICATIONS Cleanroom accessories Swab handles Totes&&

Product Description
SupplierLubrizol Advanced Materials
GenericSMMA
Material StatusCommercial: Active
FeaturesHigh purity,Rapid Static Decay,Low (to None) Ion Content,Electrostatic discharge protection,Low odor,Durability,Antistatic property
AvailabilitysNorth America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.13g/cm³ASTM D792

MECHANICALNominal valueUnitTest method
Tensile modulus1450MPaASTM D638
tensile strength
yield26.2MPaASTM D638
Tensile strain
fracture30%ASTM D638
Bending modulus1450MPaASTM D790

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch140J/mASTM D256

THERMALNominal valueUnitTest method
Hot deformation temperature ASTM D648
0.45 MPa, unannealed75.0ASTM D648
1.8 MPa, unannealed67.2ASTM D648

Electrical performanceNominal valueUnitTest method
Volume resistivity4.0E+10ohms·cmASTM D257
Electrostatic attenuation
1000 V to 10V,50% R.H.< 1.0secCPM
Surface resistance
12% R.H.6.0E+9ohmsESD S11.11
Surface resistivity
50% RH1.0E+10ohms/sqASTM D257

Supplementary informationNominal valueUnitTest method
Ion content Internal Method
Cation Na200ng/cm²Internal Method
Cl Anion20.0ng/cm²Internal Method
NO3 Anion5.00ng/cm²Internal Method
PO4 Anion15.0ng/cm²Internal Method
SO4 Anion20.0ng/cm²Internal Method
Outgassing Internal Method
MMA40.0µg/gInternal Method
Styrene15.0µg/gInternal Method
Toluene180µg/gInternal Method
Total Organics250µg/gInternal Method
FillerIDP Alloy 

Notes
1. Typical properties: these are not to be construed as specifications.
2. Test Method #3010-4
3. Test Method #3010-3
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.