About |
---|
Production-Grade Thermoplastic for Fortus 3D Production Systems PPSF/PPSU (polyphenylsulfone) material has the greatest heat and chemical resistance of all Fortus materials – ideal for aerospace, automotive and medical applications. PPSF parts manufactured on Fortus® 3D Production Systems are not only mechanically superior, but also dimensionally accurate, to better predict end-product performance. Users can also sterilize PPSF via steam autoclave, EtO sterilization, plasma sterilization, chemical sterilization and radiation. PPSF gives you the ability to manufacture Real Parts™ direct from digital files that are ideal for conceptual modeling, functional prototyping, manufacturing tools, and end-use-parts.&& |
Product Description | |
---|---|
Generic | PPSU |
Material Status | Commercial: Active |
Features | High impact resistance,Good disinfection,High pressure disinfection,High Heat Resistance,Durability,Solvent resistance,Ethylene oxide disinfection,V-0 |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.28 | g/cm³ | ASTM D792 |
ESCR(Environmental Stress Cracking Resistance) | |||
23 ℃, 50% antifreeze, 24 hours | Passed | ||
100 ℃, 50%, antifreeze, 24 hours | Passed | ||
23 ℃, unleaded gasoline, 24 hours | Passed | ||
23 ℃, lubricating oil 10W-40, 24 hours | Passed | ||
100 ℃, lubricating oil 10W-40, 24 hours | Passed | ||
23 ℃, power steering fluid, 24 hours | Passed | ||
100 ℃, power steering fluid, 24 hours | Passed | ||
23 ℃, transmission oil, 24 hours | Passed | ||
100 ℃, transmission oil, 24 hours | Passed | ||
23 ℃, 50% windshield washer fluid, 24 hours | Passed | ||
Thickness(Layer Capability) | 254.0 to 330.2 | µm |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
23℃ | 59 | J/m | ASTM D256-A |
Notched impact strength of cantilever beam | |||
23℃ | 170 | J/m | ASTM D256 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 189 | ℃ | ASTM D648 |
Glass transition temperature | 230 | ℃ | DMA |
Linear coefficient of thermal expansion | |||
MD | 5.6E-5 | 1/℃ | ASTM D696 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Dielectric strength | 3.1 to 11 | kV/mm | ASTM D149 |
Dielectric constant | 3.00 to 3.20 | ASTM D150 | |
Dissipation factor | 1.1E-3 to 1.5E-3 | ASTM D150 | |
Volumetric resistance | 5.0E+13 to 1.5E+14 | ohms | ASTM D257 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | V-0 | UL 94 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Rockwell hardness | |||
M-level | 86 | ASTM D785 | |
Tensile modulus | |||
3.18 mm | 2070 | MPa | ASTM D638 |
tensile strength | |||
3.18 mm | 55.2 | MPa | ASTM D638 |
Tensile strain | |||
Fracture, 3.18 mm | 3.0 | % | ASTM D638 |
Bending modulus | 2210 | MPa | ASTM D790 |
bending strength | 110 | MPa | ASTM D790 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. Type I, 0.20 in/min |
3. Method I (3 point load), 0.050 in/min |
4. Method A (Short-Time) |
5. All Electrical Property values were generated from the average of test plaques built with default part density (solid). Test plaques were 4.0 x 4.0 x 0.1 inches (102 x 102 x 2.5 mm) and were built both in the flat and vertical orientation. The range of values is mostly the result of the difference in properties of test plaques built in the flat vs. vertical orientation. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |