TAIRILOY® AC3100AF

About
Self Extinguishing Grade CHARACTERISTICS: High flow, Flame retardant Cl, Br, Sb free.&&

Product Description
GenericPC+ABS
Material StatusCommercial: Active
FeaturesSelf-extinguishing,Halogen free,Flame Characteristics,High liquidity,No antimony
AvailabilitysEurope,North America,Asia Pacific
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density
1.18g/cm³ASTM D792
23℃1.18g/cm³ISO 1183
Melt Flow Rate
240℃,5.0kg50g/10minASTM D1238
Shrinkage rate
MD:3.2 mm0.40 to 0.60%ASTM D955
3.2 mm0.40 to 0.60%ISO 2577

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
23℃,3.2mm590J/mASTM D256

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed, 6.35 mm88.0ASTM D648

FLAME CHARACTERISTICSNominal valueUnitTest method
1.50 mm, all colorsV-0 UL 94

MECHANICALNominal valueUnitTest method
Rockwell hardness
R-level116 ASTM D785
R-level116 ISO 2039-2
tensile strength
23℃57.0MPaASTM D638
Bending modulus
23℃2350MPaASTM D790
bending strength
23℃95.0MPaASTM D790

Process Conditions
InjectionNominal valueUnitTest method
drying temperature80 to 90°C
Drying time3.0 to 4.0hr
Recommended maximum moisture content0.020%
Hopper temperature60 to 80°C
Temperature at the rear of the barrel200 to 230°C
Temperature in the middle of the barrel220 to 250°C
Front temperature of material barrel230 to 260°C
Nozzle temperature220 to 250°C
Processing (melt) temperature230 to 260°C
Mold temperature50 to 70°C
Back pressure0.345 to 0.689MPa

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.