TARFLON ® IR1700

About

Product Description
SupplierIdemitsu
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesHigh liquidity

Technical Data
PHYSICALNominal valueUnitTest method
Shrinkage rate
MD:1.6 mm0.5 ~ 0.7%ISO 294
Density1.20g/cm³ISO 1183 B
Melt Flow Rate
300℃,1.20kg27g/10min
Water absorption rate
23℃,24hr,60% RH0.23%

MECHANICALNominal valueUnitTest method
tensile strength
fracture65MPaISO 527
yield65MPaISO 527
Nominal tensile fracture strain95%ISO 527
Tensile modulus2,000MpaISO 527
bending strength90MPaISO 178
Bending modulus2,300MPaISO 178
Rockwell hardness120/50R/M 级ISO 2039
Taber abraser12mg (1000 rounds)ASTM D1044

THERMALNominal valueUnitTest method
Vicat Softening Temp
A50145ISO 306
Hot deformation temperature
1.8 MPa125ISO 75 A
Linear coefficient of thermal expansion6,5x 10 -5 cm/cm/ºCASTM D 696

Electrical performanceNominal valueUnitTest method
Dielectric constant2.851 MHzIEC 60250
Dielectric constant2.91100 HzIEC 60250
Dielectric strength
1.6 mm30E+5kV/mmIEC 60243-1
Dissipation factor0,00921 MHzIEC 250
Arc resistance110secASTM D495
Volume resistivity8×10^20ohms·cmASTM D257

optical performanceNominal valueUnitTest method
Refractive index1,586
Total luminous transmittance85~89%ISO 13468

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant levelV-21.5mmUL 94
HB> 2.40 mm
Extreme oxygen index28%ISO 4589
Hot wire ignition 1.46 mm3UL 94
Hot filament ignition test 1.60 mm875IEC 695-2-13
Hot filament ignition test 2.00 mm875IEC 695-2-13
Hot filament ignition test 3.00 mm875IEC 695-2-13

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃40kJ/m²ISO 179

Process Conditions
InjectionNominal valueUnitTest method
Melt Temperature270 ~ 310°C
Mold temperature60 ~ 90°C
Pre drying4 hours/120°C

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.