| About |
|---|
| TECANYL™ MT is a new family of autoclavable materials developed for medical device applications. The material offers the desired performance properties of PPSU based resins with the machining ease and tool friendliness of acetal or POM. This allows part designers to take advantage of lower manufacturing costs by increasing output rates, and reducing tool wear, all without sacrificing part performance. TECANYL™ MT and TECANYL™ MT XRO™ shapes are all ISO 10993 tested to support their use in instrumentation that is intended to come in contact with blood and tissue for a period of not more than 24 hours. Ensinger can also provide TECANYL™ MT grades in finished injection molded parts for high volume applications. TECANYL™ MT exhibits a broad range of outstanding properties for applications in medical devices where exposure to extreme heat and hygienic measures are demanded. Excellent wear properties, ease of quality machining and availability in a wide range of colors contribute to its desirability in medical devices. Excellent autoclave performance comparable to higher temperature materials Easily machined, producing high quality surface No black speck generation as in sulfone polymers Lower manufacturing costs ISO 10993 Tested&& |
| Product Description | |
|---|---|
| Supplier | Ensinger |
| Generic | PPO(PPE) |
| Material Status | Commercial: Active |
| Features | Good surface appearance,Machinable,Good wear resistance,High pressure heat resistance |
| Availabilitys | North America |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | |||
| — | 1.08 | g/cm³ | ASTM D792 |
| — | 0.830 | g/cm³ | ISO 1183 |
| Water absorption rate | |||
| Equilibrium, 23 ℃ | 0.23 | % | ASTM D570 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | |||
| 23℃ | 3250 | MPa | ASTM D638 |
| tensile strength | |||
| Fracture, 23 ℃ | 67.6 | MPa | ASTM D638 |
| Tensile strain | |||
| Fracture, 23 ℃ | 16 | % | ASTM D638 |
| Bending modulus | |||
| 23℃ | 2540 | MPa | ASTM D790 |
| bending strength | |||
| 23℃ | 101 | MPa | ASTM D790 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Impact strength of cantilever beam notch | |||
| 23℃ | 140 | J/m | ASTM D256 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 1.8 MPa, unannealed | 147 | ℃ | ASTM D648 |
| Linear coefficient of thermal expansion | |||
| MD:4~38℃ | 8.7E-5 | 1/℃ | ASTM E831 |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |