TECHNYL® A 221 NATURAL

About
TECHNYL® A 221 Natural is an unfilled polyamide 66, for injection moulding, with a special crystallizing agent, for fast cycles. This grade offers a good combination between primary properties of the unreinforced polyamide 66 and processing properties leading to increased productivity. These performances are associated with excellent dimensional stability and good rigidity of moulded parts.&&

Product Description
SupplierDOMO
GenericPA66
Material StatusCommercial: Active
FeaturesNucleation,Quick molding cycle,Good Dimensional Stability,Good Rigidity,V-2
AvailabilitysAsia Pacific,Latin America,Europe,Africa & Middle East ,North America
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.14g/cm³ISO 1183/A
Water absorption rate
Equilibrium, 23 ℃, 50% RH2.9%ISO 62
23℃,24hr1.1%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃3500MPaISO 527-2/1A
tensile strength
Fracture, 23 ℃90.0MPaISO 527-2/1A
Yield, 23 ℃95.0MPaISO 527-2/1A
Yield, 23 ℃98.0MPaASTM D638
Tensile strain
Fracture, 23 ℃15%ASTM D638
Fracture, 23 ℃20%ISO 527-2
Bending modulus
23℃3200MPaASTM D790
23℃3150MPaISO 178
bending strength
23℃125MPaASTM D790
23℃125MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃4.0kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength
23℃No Break ISO 179/1eU
Impact strength of cantilever beam notch
23℃80J/mASTM D256

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed90.0ISO 75-2/Af
1.8 MPa, unannealed80.0ASTM D648
0.45 MPa, unannealed200ISO 75-2/Bf
Melting temperature263ISO 11357-3

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+15ohmsIEC 60093
Volume resistivity1.0E+15ohms·cmIEC 60093
Dielectric strength
2 mm27kV/mmIEC 60243-1
Relative permittivity2.90 IEC 60250
Dissipation factor0.030 IEC 60250
Compared to the leakage tracing index IEC 60112
Solution A600VIEC 60112
Solution B500VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
0.80 mmV-2 UL 94
1.60 mmV-2 UL 94
3.20 mmV-2 UL 94
Glowing wire flammability index
1.6 mm700IEC 60695-2-12
Extreme oxygen index26%ISO 4589-2

Process Conditions
InjectionNominal valueUnitTest method
drying temperature80°C
Recommended maximum moisture content0.20%
Temperature at the rear of the barrel265 to 275°C
Temperature in the middle of the barrel270 to 280°C
Front temperature of material barrel280 to 285°C
Mold temperature60 to 80°C

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.