About |
---|
TECHNYL® C 50H2 Natural is an unreinforced polyamide 6 based on a non-phosphorous and non-halogenated flame retardant system, heat stabilized, for injection moulding. This product, UL94 VO @ 0,4mm, offers excellent moldability together with good stiffness.&& |
Product Description | |
---|---|
Supplier | DOMO |
Generic | PA6 |
Material Status | Commercial: Active |
Features | Excellent Processability,Flame Characteristics,V-0,Good Rigidity,Heat Stabilized,Ductility |
Availabilitys | North America,Latin America,Asia Pacific,Africa & Middle East ,Europe |
Process Methods | Injection Molding,Extrusion |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.16 | g/cm³ | ISO 1183/A |
Water absorption rate | |||
23℃,24hr | 1.1 | % | ISO 62 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | |||
23℃ | 3500 | MPa | ISO 527-2/1A |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Surface resistivity | 1.0E+15 | ohms | IEC 60093 |
Volume resistivity | 1.0E+15 | ohms·cm | IEC 60093 |
Dielectric strength | |||
2 mm | 34 | kV/mm | IEC 60243-1 |
Relative permittivity | 3.50 | IEC 60250 | |
Dissipation factor | 0.020 | IEC 60250 | |
Compared to the leakage tracing index | IEC 60112 | ||
Solution A | 600 | V | IEC 60112 |
Solution B | 475 | V | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
0.40 mm | V-0 | UL 94 | |
Glowing wire flammability index | IEC 60695-2-12 | ||
0.80 mm | 960 | ℃ | IEC 60695-2-12 |
1.6 mm | 960 | ℃ | IEC 60695-2-12 |
3.2 mm | 960 | ℃ | IEC 60695-2-12 |
Igniting temperature of the hot wire | IEC 60695-2-13 | ||
0.8 mm | 700 | ℃ | IEC 60695-2-13 |
1.6 mm | 700 | ℃ | IEC 60695-2-13 |
3.2 mm | 700 | ℃ | IEC 60695-2-13 |
Extreme oxygen index | 36 | % | ISO 4589-2 |
French Fire Index | F2 | NF F16-101 | |
French Smoke Index | I2 | NF F16-101 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
European Railway Certification | EN 45545-2 | ||
R22 | HL3 | EN 45545-2 | |
R23 | HL3 | EN 45545-2 | |
R25 | HL3 | EN 45545-2 |
Process Conditions | |||
---|---|---|---|
Injection | Nominal value | Unit | Test method |
drying temperature | 80 | °C | |
Recommended maximum moisture content | 0.20 | % | |
Temperature at the rear of the barrel | 230 to 235 | °C | |
Temperature in the middle of the barrel | 235 to 240 | °C | |
Front temperature of material barrel | 235 to 245 | °C | |
Mold temperature | 60 to 90 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |