| About |
|---|
| TECHNYL STAR® AF 60SX V30 GREY 7035 LPU is a polyamide 66 based on a non halogenated flame retardant system, reinforced with 30% of glass fiber, for injection moulding. This grade offers, in addition to a high flow matrix and a good combination of fire properties, the particularity to decrease the level of blooming/exudation phenomena during the life time of the application.&& |
| Product Description | |
|---|---|
| Supplier | DOMO |
| Generic | PA66 |
| Material Status | Commercial: Active |
| Features | Low Halogen Content,High liquidity,Good stripping performance,Good surface appearance |
| Availabilitys | Europe,Africa & Middle East |
| Process Methods | Injection Molding |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.46 | g/cm³ | |
| Shrinkage rate | |||
| TD | 1.0 | % | |
| MD | 0.30 | % | |
| Water absorption rate | |||
| 23℃,24hr | 0.70 | % | |
| Saturation, 23 ℃ | 4.1 | % | |
| Equilibrium, 23 ℃, 50% RH | 1.7 | % | |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | |||
| 23℃ | 10800 | MPa | |
| tensile strength | |||
| Fracture, 23 ℃ | 105 | MPa | |
| Tensile strain | |||
| Fracture, 23 ℃ | 1.5 | % |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Charpy Unnotch Impact strength | |||
| 23℃ | 33 | kJ/m² |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 0.45 MPa, unannealed | 262 | ℃ | |
| 1.8 MPa, unannealed | 243 | ℃ | |
| Melting temperature | 263 | ℃ |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Dielectric strength | |||
| 0.8 mm | 37 | kV/mm | |
| Compared to the leakage tracing index | |||
| Solution A | 600 | V |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Flame retardant level | |||
| 0.80 mm | V-0 | ||
| 1.60 mm | |||
| 3.20 mm | |||
| Glowing wire flammability index | |||
| 0.80 mm | 960 | ℃ | |
| 1.6 mm | 960 | ℃ | |
| 3.2 mm | 960 | ℃ | |
| Igniting temperature of the hot wire | |||
| 0.8 mm | 750 | ℃ | |
| Extreme oxygen index | 33 | % |
| Supplementary information | Nominal value | Unit | Test method |
|---|---|---|---|
| European Railway Certification | |||
| R22 | HL3 | ||
| R23 | HL3 |
| Process Conditions | |||
|---|---|---|---|
| Injection | Nominal value | Unit | Test method |
| Injection instructions | Nominal value | Unit | Test method |
| drying temperature | 80 | °C | |
| Recommended maximum moisture content | 0.20 | % | |
| Temperature at the rear of the barrel | 260 to 270 | °C | |
| Temperature in the middle of the barrel | 265 to 275 | °C | |
| Front temperature of material barrel | 265 to 280 | °C | |
| Mold temperature | 60 to 90 | °C | |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |