About |
---|
TECHNYL STAR® S 60X1 V30 Natural is a grade based on a non-halogenated flame retardant system and on a patented high flow polyamide 6 resin (TechnylStar), reinforced of 30% of glass fiber, heat stabilized, for injection moulding. This grade is Heat stabilized and provides optimized injection moulding performance.&& |
Product Description | |
---|---|
Supplier | DOMO |
Generic | PA6 |
Material Status | Commercial: Active |
Features | low-temperature impact resistance,Good stripping performance,Halogen free,Arc resistance,Good surface appearance,Corrosion Resistant,High liquidity |
Availabilitys | Africa & Middle East ,Europe,Asia Pacific |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.42 | g/cm³ | ISO 1183 |
Water Absorption | |||
24 h,23℃ | 0.9 | % | ISO 62 |
4.2 | % | ISO 62 | |
Molding shrinkage | |||
Parallel, 72 hours, 23 ℃, 50% r. h | 0.25 | % | ISO 294-4 |
Normal, 72 hours, 23 ℃, 50% r. h | 0.8 | % | ISO 294-4 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile Modulus | |||
Dry | 11000 | MPa | ISO 527 |
Wet Cond | 7200 | MPa | ISO 527 |
Tensile Strength | |||
Broken BRK, dry dry | 155 | MPa | ISO 527-2 |
Broken BRK, wet Cond | 97 | MPa | ISO 527-2 |
Tensile Strain | |||
Broken BRK, dry dry | 2.8 | % | ISO 527 |
Broken BRK, wet Cond | 5 | % | ISO 527 |
Flexural Modulus | |||
Dry | 9450 | MPa | ISO 178 |
Wet Cond | 5400 | MPa | ISO 178 |
Dry | 10100 | MPa | ASTM D790 |
Flexural Strength | |||
Dry | 248 | MPa | ISO 178 |
Wet Cond | 167 | MPa | ISO 178 |
Dry | 222 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Unnotch Impact strength | |||
23 ℃, dry | 65 | kJ/m² | ISO 179/1eU |
23 ℃, moist cond | 70 | kJ/m² | ISO 179/1eU |
-30 ℃, dry | 50 | kJ/m² | ISO 179/1eU |
Charpy Notched Impact Strength | |||
23 ℃, dry | 10 | kJ/m² | ISO 179/1eA |
23 ℃, moist cond | 13 | kJ/m² | ISO 179/1eA |
-30 ℃, dry | 9 | kJ/m² | ISO 179/1eA |
Izod Unnotched Impact strength of cantilever beam | |||
23 ℃, dry | 54 | KJ/m² | ISO 180/1U |
23 ℃, moist cond | 63 | KJ/m² | ISO 180/1U |
Izod Notched Impact strength | |||
23 ℃, dry | 10 | KJ/m² | ISO 180/1A |
23 ℃, moist cond | 12 | KJ/m² | ISO 180/1A |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Melting temperature | 222 | ℃ | ISO 11357-3 |
Hot deformation temperature HDT | |||
1.80 MPa | 205 | ℃ | ISO 75-1/-2 |
ELECTRICAL | Nominal value | Unit | Test method |
---|---|---|---|
Volume Resistance | 1E13 | ohm·m | IEC 62631-3-1 |
Surface Resistivity | 6E14 | ohm | IEC 62631-3-1 |
Compared Tracking Index | 600 | V | IEC 60112 |
Dielectric Strength | 25 | kV/mm | IEC 60243-1 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame Class Rating | |||
0.75 mm | V-0 | UL 94 | |
1.5 mm | 5VA | UL 94 | |
3.0 mm | 5VA | UL 94 | |
Glow Wire Flammability Index (GWFI) | |||
0.75 mm | 960 | ℃ | IEC 60695-2-12 |
1.5 mm | 960 | ℃ | IEC 60695-2-12 |
3.0 mm | 960 | ℃ | IEC 60695-2-12 |
Glow Wire Ignitability Temperature (GWIT) | |||
0.75 mm | 775 | ℃ | IEC 60695-2-13 |
1.5 mm | 800 | ℃ | IEC 60695-2-13 |
3.0 mm | 825 | ℃ | IEC 60695-2-13 |
Oxygen Index | 35 | % | ISO 4589-2 |
Process Conditions | |||
---|---|---|---|
Injection Molding | Nominal value | Unit | Test method |
Drying Temperature | 80 | ℃ | |
Maximum Moisture Content | 0.2 | % | |
Rear Temperature Zone 1 | 230-235 | ℃ | |
Middle Temperature Zone 2 | 235-240 | ℃ | |
Front Temperature Zone 3 | 240-245 | ℃ | |
Mold Temperature | 60-90 | ℃ |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |