| About |
|---|
| Therma-Tech™ Thermal Management Compounds have been engineered to combine the heat transfer and cooling capabilities of metals with the design freedom, weight reduction and cost advantages of thermoplastics. These materials provide the benefits of proprietary conductive additive technologies and the performance of select engineering thermoplastic resins. Therma-Tech compounds have been shown to improve thermal conductivity up to 100-times that of conventional plastics and can be used in a wide range of thermal management applications.&& |
| Product Description | |
|---|---|
| Supplier | Polyone |
| Generic | PPS |
| Material Status | Commercial: Active |
| Features | Conductive,Thermal conductivity,V-0,5VA |
| Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
| Process Methods | Extrusion |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.79 | g/cm³ | ISO 1183 |
| Shrinkage rate | |||
| MD: Injection molding | 0.10 to 0.30 | % | ISO 294-4 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | 17500 | MPa | ISO 527 |
| tensile strength | |||
| fracture | 64.0 | MPa | ISO 527-2/1/50 |
| Tensile strain | |||
| fracture | 0.30 to 0.50 | % | ISO 527 |
| Bending modulus | |||
| injection molding | 16000 | MPa | ISO 178 |
| bending strength | |||
| injection molding | 90.0 | MPa | ISO 178 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Charpy Notched Impact Strength | |||
| 23℃ | 2.8 | kJ/m² | ISO 179 |
| Charpy Unnotch Impact strength | |||
| 23℃ | 6.3 | kJ/m² | ISO 179 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 1.8 MPa, unannealed | 240 | ℃ | ISO 75-2/A |
| Thermal conductivity coefficient | 2.0 to 2.4 | W/m/K |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Surface resistivity | < 1.0E+4 | ohms | IEC 60093 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Flame retardant level | UL 94 | ||
| 0.80 mm | V-0 | UL 94 | |
| 1.50 mm | 5VA | UL 94 | |
| 3.00 mm | 5VA | UL 94 | |
| Glowing wire flammability index | IEC 60695-2-12 | ||
| 0.80 mm | 960 | ℃ | IEC 60695-2-12 |
| 1.6 mm | 960 | ℃ | IEC 60695-2-12 |
| 3.0 mm | > 960 | ℃ | IEC 60695-2-12 |
| Igniting temperature of the hot wire | IEC 60695-2-13 | ||
| 1.6 mm | > 960 | ℃ | IEC 60695-2-13 |
| 3 mm | > 960 | ℃ | IEC 60695-2-13 |
| Process Conditions | |||
|---|---|---|---|
| injection | Nominal value | Unit | Test method |
| Processing (melt) temperature | 310 to 340 | °C | |
| Mold temperature | 140 to 170 | °C | |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 2. Type I, 0.039 in/min |
| 3. Type I, 2.0 in/min |
| 4. 0.39 in/min |
| 5. Through Plane with Modified Transient Plane Source technique, C-Therm TCi™ |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |